Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:330907-05-30-70-02-CN
330907-05-30-70-02-CN Reverse Mount Probe Bently Nevada
Manufacturer: Bently Nevada
Product No.: 330907-05-30-70-02-CN
Product Type: Reverse Mount Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Bently Nevada 330907-05-30-70-02-CN is a 3300 NSv reverse mount eddy current probe for process compressor bearing and thrust position monitoring. The NSv platform raises chemical resistance over the 3300 RAM probe, and its side-view performance beats the 3000-series 190 probe at the same target gap. Factory DC resistance measures 5.9 ± 0.9 Ω across the 7.0 m (23.0 ft) cable, and the probe weighs roughly 14 to 150 g (0.5 to 5.3 oz) depending on case option.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | 330907-05-30-70-02-CN |
| Probe Type | 3300 NSv Reverse Mount |
| Thread | M10 × 1 |
| Max Thread Engagement | 15 mm |
| Total Length | 7.0 m (23.0 ft) |
| Connector | Miniature ClickLoc Coaxial |
| DC Resistance (RPROBE) | 5.9 ± 0.9 Ω |
| Linear Range | 0.25 mm to 1.75 mm (10 to 70 mils), approx. -1 to -13 Vdc |
| Recommended Gap | 1.0 mm (40 mils) |
| Field Wiring | 0.2–1.5 mm² (16–24 AWG); 0.25–0.75 mm² (18–23 AWG) with ferrules |
| Max Cable Run | 305 m (1,000 ft) to monitor |
| Probe Tip Material | Polyphenylene Sulfide (PPS) |
| Probe Case Material | AISI 304 Stainless Steel |
| Probe Weight | Approx. 14–150 g (0.5–5.3 oz) |
| Case Torque | Max 22.6 N·m (200 in·lb), Recommended 7.5 N·m (66 in·lb) |
| Operating Temperature | -52 °C to +177 °C (-62 °F to +351 °F) |
| Storage Temperature | -52 °C to +177 °C (-62 °F to +351 °F) |
| Pressure Seal | Viton O-ring |
| Agency Approval | -CN (Country Specific) |
Installation Guide
Mount the probe through the bearing housing with the side-view tip aimed at the shaft surface, tightening to the recommended 7.5 N·m (66 in·lb) and never exceeding 22.6 N·m (200 in·lb). Set the gap at 1.0 mm (40 mils) and confirm the Proximitor output reads approximately -10 Vdc. Keep cable bend radius above 25 mm and route the ClickLoc connection clear of oil pooling. Use three-conductor shielded triad cable for field runs, with ferrules on 0.25–0.75 mm² conductors. For hazardous areas, wire the loop with the certified barriers required by the -CN approval. Avoid sustained exposure below -34 °C (-30 °F), which may cause premature pressure seal failure.
Engineering Advantages
The 3300 NSv probe carries higher chemical resistance than the 3300 RAM, suiting sour process compressor environments. Its side-view characteristics beat the 3000-series 190 probe when gapped at the same distance, giving cleaner signal in tight radial clearances. TipLoc molding locks the tip to the body, and gold-plated ClickLoc connectors stay seated under vibration. A probe weight of only 14 to 150 g (0.5 to 5.3 oz) adds minimal load to bearing housings, and the 305 m (1,000 ft) cable run gives flexible monitor cabinet placement. The -CN approval covers local hazardous area certification for Chinese refinery and power plant installations.
Technical FAQs
Q1: What gap voltage should I target at 1.0 mm?
A1: At a 1.0 mm (40 mil) gap, the Proximitor output reads approximately -10 Vdc near the center of the linear range. Verify against the monitor calibration curve for your system length.
Q2: What does the -CN suffix mean?
A2: -CN indicates Country Specific Approval, covering local hazardous area certification requirements for the destination market.
Q3: How much torque does the M10 reverse mount need?
A3: Tighten to the recommended 7.5 N·m (66 in·lb) and never exceed 22.6 N·m (200 in·lb) to avoid thread or case damage.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Do You Tune a 3500/92 Gateway for Stable Modbus TCP Polling?
This article explains why Bently Nevada 3500/92 Modbus TCP gateways fail in industrial control systems and how automa...
-
How Can You Prevent GE PLC Backup Failures?
This article explains why GE PLC backup failures occur in RX3i and VersaMax environments. It presents measured root c...
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
