Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:330130-070-00-05
330130-070-00-05 3300 XL Non-Armored Cable Bently Nevada
Manufacturer: Bently Nevada
Product No.: 330130-070-00-05
Product Type: Extension Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 103g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Description
Product Overview
The 330130-070-00-05 is a premium 7.0-meter non-armored standard extension cable manufactured in the U.S.A. for the industry-standard Bently Nevada 3300 XL 8mm Proximity Transducer System. This high-precision coaxial cable transmits critical eddy current frequency signals between proximity probes and Proximitor Sensors. It plays an indispensable role in monitoring shaft vibration, position, and radial speed on high-speed rotating machinery—such as steam turbines, centrifugal compressors, and large industrial pumps—ensuring reliable data for critical asset protection loops.
Core Technical Advantages
-
Detailed Suffix Logic Breakdown:
- -070: Configures a precise total electrical and physical cable length of 7.0 meters (22.9 feet).
- -00: Specifies a standard, lightweight non-armored cable configuration for optimized routing within conduit channels.
- -05: Confirms international hazardous area safety approvals including CSA, ATEX, and IECEx certifications.
- Engineered Electrical Performance: Features strict factory-calibrated DC resistance tolerances ($1.54 \pm 0.23\,\Omega$ core resistance) to prevent signal drift and maintain baseline loop calibration.
- Optimized Capacitance Profile: Maintains a low typical capacitance of 69.9 pF/m (21.3 pF/ft), preventing signal attenuation and roll-off over extended measurement loops.
- Hazardous Deployment Ready: Certified for implementation in volatile environments when integrated with nonincendive circuits or isolated safety barriers.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Number | 330130-070-00-05 |
| Manufacturer / Origin | Bently Nevada / Made in U.S.A. |
| Cable Length Option | 7.0 meters (22.9 feet) |
| Cable Protection Type | Standard Cable (Non-Armored) |
| Core Resistance ($R_{CORE}$) | 1.54 $\pm$ 0.23 $\Omega$ (Center Conductor to Center Conductor) |
| Jacket Resistance ($R_{JACKET}$) | 0.46 $\pm$ 0.09 $\Omega$ (Outer Conductor to Outer Conductor) |
| Typical Capacitance | 69.9 pF/m (21.3 pF/ft) |
| Total Mass Weight | 34 g/m (Total net mass: 0.204 kg) |
| Agency Approvals | CSA, ATEX, IECEx |
| Transducer Linear Range | 2 mm (80 mils), spans from 0.25 to 2.3 mm (10 to 90 mils) |
Installation & Maintenance Guide
Connector Sealing Constraints
Each 330130-070-00-05 cable ships with specialized silicone sealing tape. While this tape can replace rigid mechanical connector protectors in mild environments, you must never utilize silicone tape if the probe-to-extension connector joint faces direct exposure to corrosive turbine oil. Use oil-tight connector protectors instead.
Field Wiring and Monitor Distance
When routing data from the Proximitor Sensor to a monitoring rack, employ high-quality 3-conductor shielded triad field wiring (0.2 to 1.5 mm² or 16 to 24 AWG) with tinned leads. Keep the maximum field wiring distance below 305 meters (1,000 feet) to prevent high-frequency signal roll-off or amplitude attenuation.
Power Rail and Barrier Matching
The companion Proximitor Sensor requires a stable -17.5 Vdc to -26 Vdc supply for nonincendive loops, drawing 12 mA maximum. If safety barriers are installed, the voltage must remain restricted between -23 Vdc and -26 Vdc. Operating the loop at a voltage more positive than -23.5 Vdc can degrade the 2 mm linear calibration spectrum.
Engineering Advantages
- Exceptional Moisture Stability: Exhibits less than a 3% change in Average Scale Factor (ASF) even when tested across continuous 93% relative humidity for 56 straight days under IEC standard 68-2-3 conditions.
- Reduced Mechanical Weight Profile: Weighing only 34 g/m compared to the 103 g/m armored variant, this standard profile puts significantly less physical stress on suspended junction layouts.
- Flawless System Accuracy: Pre-calibrated to deliver full dynamic accuracy when matched with standard AISI 4140 steel targets, a 3300 XL 8mm probe, and a -24 Vdc source gapped at 1.27 mm (50 mils).
Technical FAQs
Q1: What is the main structural difference between the -00 and -01 cable option?
A1: The -00 suffix denotes a lightweight standard cable profile lacking external metal wrap. Option -01 includes a heavy stainless steel flexible armor outer layer. Use -00 inside protective metal conduits or wiring trays.
Q2: Why is silicone tape banned in areas exposed to turbine oil?
A2: Turbine oil can degrade and break down silicone adhesives over time. If fluid bypasses the tape barrier and coats the coaxial interface, it creates signal contamination, causing false vibration alarms or system trips.
Q3: Does this 7-meter extension cable include FluidLoc liquid mitigation?
A3: No, the -00 option is a standard high-performance cable. If your engineering prints mandate internal oil-block seals to prevent migration through the cable core, a specialized FluidLoc-configured assembly variant must be specified.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...