Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:2300/20-CN
2300/20-CN Bently Nevada 4-20mA Output Monitor
Manufacturer: Bently Nevada
Product No.: 2300/20-CN
Product Type: Vibration Monitor
Product Origin: USA
Payment:T/T, Western Union
Weight: 1030g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Bently Nevada 2300/20-CN provides high-performance, cost-effective vibration monitoring for essential balance-of-plant (BOP) machinery. Specifically engineered for small-to-medium rotating equipment like motors, pumps, and fans, this dual-channel monitor excels in capturing critical mechanical data. By utilizing high-precision signal processing, the 2300/20-CN ensures early detection of faults such as imbalance and bearing wear, delivering the industry-standard protection Bently Nevada is known for in a compact, standalone format.
Technical Specifications
| Feature | Specification |
|---|---|
| Manufacturer | Bently Nevada (Made in U.S.A) |
| Input Channels | 2-Channel Seismic (Accelerometers/Velocity) |
| Analog Output | Dual 4-20 mA (Isolated) |
| Communication | RS485 Modbus RTU |
| Power Supply | 18~36 VDC, 6.5 W |
| Protection Class | IP65 (Dust & Water Resistant) |
| Operating Temp | -30 °C to +65 °C (-22 °F to +149 °F) |
Core Technical Advantages
Seamless DCS Integration
The monitor converts complex seismic signals into dual isolated 4-20mA outputs. This allows your existing PLC or DCS to trigger alarms and shutdowns instantly, without the latency or complexity associated with proprietary rack software.
Enhanced EMI Immunity
Equipped with an internally isolated power architecture, the 2300/20-CN effectively rejects electromagnetic interference caused by Variable Frequency Drives (VFDs) and large switchgear, ensuring stable and reliable readings in noisy industrial environments.
Smart Edge Diagnostics
The integrated RS485 Modbus RTU port transforms the hardware into an intelligent edge device. Maintenance teams can remotely poll detailed diagnostic data and trend machine health over time for superior predictive maintenance.
Installation & Maintenance
- Mounting: Fixed-mount the IP65-rated housing near the machinery to minimize signal loss.
- Shielding: Utilize shielded twisted-pair cables, grounding the shield strictly at the monitor end to eliminate ground loops.
- Fault Logic: The 4-20mA loop is designed to drop below 4mA (typically to 2mA) to signal a "Sensor Not OK" status for rapid troubleshooting.
Engineering Advantages
The 2300/20-CN offers the same high-tier measurement algorithms found in Bently Nevada’s flagship 3500 series but at a fraction of the cost. Its rugged build handles extreme climates (-30°C to +65°C), making it the perfect upgrade path for replacing outdated vibration switches or simple analog transmitters with a digital-ready solution.
Technical FAQs
Q1: What does the "CN" suffix indicate?
A1: The "CN" designation signifies regional certification for the Chinese market. The hardware and technical performance are identical to the standard global 2300/20 series.
Q2: Is this compatible with proximity probes?
A2: No, this specific model is designed for seismic sensors (accelerometers/velocity transducers). For eddy current probe applications, please consult our 1900/65A or 3500 series inventory.
Q3: Does it require special software for basic 4-20mA monitoring?
A3: No. The 4-20mA outputs are hard-scaled, allowing for direct "plug-and-play" connection to any standard industrial controller.
Goşmaça spesifikasiýalar
- Gök
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...