Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1794-PS3
1794-PS3 Allen-Bradley Flex I/O Power Supply 24VDC 3A
Manufacturer: Allen-Bradley
Product No.: 1794-PS3
Product Type: Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley 1794-PS3 Flex I/O Power Supply
Product Overview
The Allen-Bradley 1794-PS3 is a Flex I/O power supply module providing 24 VDC nominal output at 3 A (horizontal mounting) or 2.8 A (other mountings) with 72 W output power. It accepts 85-264 VAC input (47-63 Hz) and delivers sufficient surge to drive up to 10 adapters. The module features 2500 VDC isolation and 40 A typical inrush current. Weight is 0.45 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1794-PS3 |
| Product Family | Flex I/O System |
| Product Type | Flex I/O DC Power Supply Module |
| Input Voltage Range | 85-264 VAC |
| Input Frequency Range | 47-63 Hz |
| Nominal Input Voltage | 120 VAC (1.7 A max) / 230 VAC (1.1 A max) |
| Maximum Input Current | 1.9 A |
| Inrush Current | 40 A Typical, 1 AC Cycle @ 265 VAC, 55 °C |
| Output Voltage | 24 VDC Nominal |
| Output Voltage Range | 20.4-27.6 VDC |
| Output Current (Horizontal) | 3 A |
| Output Current (Other) | 2.8 A |
| Output Power | 72 W |
| Output Surge | Sufficient to Drive 10 Adapters |
| Output Ripple | 1200 mV Peak-to-Peak (±5%) |
| Overcurrent Protection | 3.2 A |
| Overvoltage Protection | 35 VDC |
| Isolation Voltage | 2500 VDC |
| Minimum Load | 50 mA |
| Leakage Current | 0.5 mA RMS Max |
| Power Dissipation | 12 W Max |
| Thermal Dissipation | 41.0 BTU/hr |
| Hold-Up Time | 1/2 Cycle @ 47 Hz, 85 VAC, Max Load |
| Input Power | 86 W |
| Max Apparent Input Power | 205 VA |
| Max Transformer Load | 250 VA |
| Dimensions (H x W x D) | 3.7 x 2.7 x 3.4 in |
| Enclosure Type | Open Style |
| Mounting | DIN Rail or Panel Mount (Horizontal/Vertical) |
| Operating Temperature | 0 to +55 °C |
| Operating Shock | 30g |
| Operating Vibration | 5g @ 10-500 Hz |
| Weight | 0.45 kg |
| UPC | 10612598206626 |
Key Features
- Wide input voltage range 85-264 VAC, 47-63 Hz
- 24 VDC nominal output at 3 A (horizontal) or 2.8 A (other mountings)
- 72 W output power with 1200 mV peak-to-peak ripple
- Output surge sufficient to drive up to 10 adapters
- 2500 VDC isolation between AC input and DC output
- 40 A typical inrush current handling
- 3.2 A overcurrent protection and 35 VDC overvoltage protection
- Hold-up time of 1/2 cycle at 47 Hz, 85 VAC with max load
- DIN rail or panel mount in horizontal or vertical orientation
- 30g operating shock and 5g vibration resistance
Installation Notes
Mount the power supply using DIN rail or panel mount in horizontal or vertical orientation. Horizontal mounting allows 3 A output current, while other orientations support 2.8 A. Connect 85-264 VAC input at 47-63 Hz. The output provides 24 VDC nominal to power Flex I/O modules and adapters. Maintain minimum load of 50 mA. The unit supports up to 10 Flex I/O adapters through its output surge capability. Maintain operating temperature between 0 and +55 °C. Ensure proper isolation between DC output terminals and AC input terminals.
FAQs
Q1: What is the output power of the 1794-PS3?
A1: 72 W with 3 A output current at horizontal mounting or 2.8 A at other mountings.
Q2: How many adapters can this power supply drive?
A2: Output surge is sufficient to drive up to 10 Flex I/O adapters.
Q3: What is the inrush current rating?
A3: 40 A typical for 1 AC cycle at 265 VAC and 55 °C.
Goşmaça spesifikasiýalar
- Çal
- AC tok bilen işleýän
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
-
How Does Bently Nevada Balancing Stabilize Turbo Machinery?
This article explains how Bently Nevada TSI instruments enable practical field dynamic balancing for turbo machinery....
-
What Makes GE Historian Ideal for Industrial Time-Series Storage?
GE Historian delivers optimized long-term industrial time-series storage for control systems. It compresses OT data b...