Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1769-L33ER
1769-L33ER Allen-Bradley CompactLogix Processor Module
Manufacturer: Allen-Bradley
Product No.: 1769-L33ER
Product Type: Controller Processor
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1769-L33ER is a high-performance CompactLogix 5370 L3 controller designed to meet the growing demands of mid-range application scales. As a core processor module in the Integrated Architecture, it provides a scalable solution for motion, safety, and standard control. Featuring dual Ethernet/IP ports for linear and Device Level Ring (DLR) topologies, this controller enables seamless integration and high-speed communication across industrial networks.
Technical Configuration
- Manufacturer: Allen-Bradley / Rockwell Automation
- Model Series: CompactLogix 5370
- Module Type: Processor / Controller Module
- Communication Ports: 1 USB Port (Console); 2 Ethernet Ports (Integrated Switch)
- Network Support: EtherNet/IP (DLR, Linear, and Star Topologies)
- I/O Capacity: Supports up to 32 Local I/O Modules
- Expansion Capability: Up to 3 I/O Banks
Technical Specifications
| Net Weight | 0.45 kg (0.99 lbs) | Power Dissipation | 4.5 W (Max) |
| Module Width | 55.00 mm (2.17 in.) | Tasks Supported | 32 Tasks |
| Execution | 100 Programs per Task; User Memory 2 MB | ||
Installation & Programming
1. Mounting and Power: The 1769-L33ER installs directly onto a standard DIN rail or can be panel-mounted. Ensure that the power supply distance rating is observed; the controller must be within 4 modules of the 1769 power supply to ensure voltage stability and peak performance of the internal 4.5 W dissipation circuit.
2. Network Topology: Utilize the dual Ethernet ports to create a Device Level Ring (DLR) for high availability. This allows the system to remain operational even if a single point in the network cable is severed. The USB port is intended solely for local programming, firmware updates, and configuration via Studio 5000 Logix Designer® software.
3. I/O Management: This processor supports a massive local I/O footprint of up to 32 modules across 3 banks. When expanding to multiple banks, use 1769-CRR1/CRR3 or 1769-CRL1/CRL3 expansion cables to maintain backplane communication integrity.
Engineering Advantages
The Allen-Bradley CompactLogix 5370 series brings the benefits of the Common Control Engine to a smaller form factor. The 1769-L33ER eliminates the need for a battery by utilizing internal non-volatile memory for storage, significantly reducing maintenance requirements. With the ability to manage 32 tasks and 100 programs per task, it offers the multitasking power usually reserved for larger ControlLogix systems, making it the premier choice for complex machine control and high-speed material handling.
Technical FAQs
Q1: Does the 1769-L33ER require a battery?
A1: No, the CompactLogix 5370 controllers use an internal energy storage module to write data to the onboard non-volatile memory during a power loss, eliminating the need for lithium batteries.
Q2: Can I use this controller for Integrated Motion on EtherNet/IP?
A2: Yes, the L33ER supports Integrated Motion on EtherNet/IP for up to 8 axes, providing a synchronized control solution for servo drives.
Q3: What software is required for configuration?
A3: You will need Studio 5000 Logix Designer® (formerly RSLogix 5000) software, typically Version 20 or higher, depending on your firmware revision.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
