Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1763-L16BWA
1763-L16BWA | MicroLogix 1100 Controller 6 Relay Allen-Bradley
Manufacturer: Allen-Bradley
Product No.: 1763-L16BWA
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley 1763-L16BWA MicroLogix 1100 Programmable Controller
Product Overview
Allen-Bradley 1763-L16BWA is a MicroLogix 1100 programmable controller with 18 I/O points. Features 10 discrete 24V DC sinking or sourcing inputs (4 high speed), 2 analog 0 to 10VDC inputs, and 6 individually isolated relay outputs. Powered by 120 to 240V AC supply. Integrated RS232/485 and Ethernet communication ports with built-in LCD display. Supports up to 4 expansion modules.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1763-L16BWA |
| Series | MicroLogix 1100 |
| Type | Programmable Controller |
| Input Power | 120 to 240V AC |
| Operating Frequency | 47 to 63 Hz |
| Power Consumption | 52 VA |
| Inrush Current | 25A at 120V AC (8 ms), 40A at 240V AC (4 ms) |
| Point Count | 18 I/O points |
| Digital Inputs | 10 x 24V DC sink/source (4 high speed) |
| Analog Inputs | 2 x 0 to 10VDC |
| Analog Resolution | 10 bit unsigned integer |
| Analog Accuracy | ±0.5% full scale |
| Analog Impedance | 210 kOhm |
| Relay Outputs | 6 x individually isolated |
| Relay Voltage Range | 125V DC, 120 240V AC |
| Relay Current | 1.0A continuous (3A per group) |
| Relay Response Time | 10 ms ON/OFF |
| Communication | RS232/485, Ethernet 10/100 Mbps |
| Memory | Non volatile battery backed RAM |
| Display | LCD |
| Expansion Modules | Up to 4 |
| Operating Temperature | 20°C to +65°C |
| Humidity | 5% to 95% non condensing |
| Shock Rating | 30 G operating |
| Vibration Resistance | 15 G at 50 Hz |
| Dimensions | 3.5 x 4.09 x 3.43 inches |
| Weight | 0.91 kg (2.0 lbs) |
| UPC | 10662074023032 |
Installation
Mount controller in industrial enclosure. Connect 120 to 240V AC power supply. Wire 24V DC inputs for sink or source configuration. Use Belden #8761 cable for analog channels with drain wire and foil shield connected to grounding system. Analog channels support 2 wire, 3 wire, and 4 wire transmitters. Controller does not provide loop power for analog voltage input. Configure parameters via LCD display or Ethernet port.
Features
10 discrete 24V DC sink/source inputs with 4 high speed channels. 2 analog 0 to 10VDC inputs with 10 bit resolution and ±0.5% accuracy. 6 individually isolated relay outputs rated 1.0A continuous. Integrated RS232/485 and Ethernet 10/100 Mbps. Supports up to 4 expansion modules. Non volatile battery backed RAM. Built in LCD for configuration and data monitoring. Operational shock 30G and vibration 15G at 50 Hz.
FAQ
Q1: How many I/O points does this controller have?
A1: 18 I/O points: 10 discrete 24V DC inputs (4 high speed), 2 analog 0 to 10VDC inputs, and 6 individually isolated relay outputs.
Q2: What expansion capability does this controller support?
A2: Supports up to 4 expansion modules to enhance integrated features of the controller.
Q3: What cable is recommended for analog inputs?
A3: Belden #8761 cable with drain wire and foil shield connected to grounding system. Supports 2 wire, 3 wire, and 4 wire transmitters.
Goşmaça spesifikasiýalar
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...
