Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:ATV71H037M3
0.37 kW Variable Speed Drive | IP20 Schneider ATV71H037M3
Manufacturer: Schneider
Product No.: ATV71H037M3
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 3000g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Schneider ATV71H037M3 is a variable speed drive from the Altivar 71 series, engineered for complex, high-power machines. It delivers 0.37 kW (0.5 HP) motor power from a 200-240V three-phase supply. Weighing 3 kg net (0.94 kg gross), this compact model includes a heat sink and integrated EMC filter. It supports synchronous and asynchronous motors with Modbus and CANopen communication.
Technical Configuration
This drive provides 3 A nominal output current at 4 kHz for 230V three-phase operation. Maximum transient current reaches 4.5 A for 60 seconds or 4.9 A for 2 seconds. Output frequency spans 0.1 to 599 Hz with adjustable switching frequency from 1 to 16 kHz. Motor control profiles include voltage/frequency ratio, sensorless flux vector control (SFVC), and flux vector control (FVC) with sensor feedback. Speed accuracy reaches ±0.01% of nominal speed in closed-loop mode with encoder feedback.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Product Line | Altivar 71 |
| Part Number | ATV71H037M3 |
| Motor Power | 0.37 kW (0.5 HP), 3 phase 200-240V |
| Supply Voltage | 200-240V (-15%, +10%) |
| Supply Voltage Limits | 170-264V |
| Supply Frequency | 50-60 Hz ±5% (47.5-63 Hz) |
| Line Current | 3.1 A at 240V; 3.5 A at 200V |
| Nominal Output Current | 3 A at 4 kHz |
| Max Transient Current | 4.5 A for 60 s; 4.9 A for 2 s |
| Output Frequency | 0.1-599 Hz |
| Switching Frequency | 1-16 kHz adjustable (4-16 kHz with derating) |
| Transient Overtorque | 170% for 60 s; 220% for 2 s |
| Max Motor Cable Length | 50 m shielded; 100 m unshielded |
| EMC Filter | Integrated |
| Analogue Inputs | 2 (bipolar ±10V DC; configurable current/voltage) |
| Analogue Outputs | 1 (configurable logic, current, or voltage) |
| Discrete Inputs | 7 (24V DC; LI6 configurable PTC probe; PWR safety input) |
| Discrete Outputs | 2 configurable relay logic (R1 NO/NC, R2 NO) |
| Communication Protocols | Modbus, CANopen |
| Operating Temperature | -10 to 50°C (14 to 122°F) without derating |
| Storage Temperature | -25 to 70°C (-13 to 158°F) |
| Relative Humidity | 5-95% without condensation |
| Operating Altitude | ≤1000 m without derating; 1% per 100 m above |
| IP Rating | IP20 upper, IP21, IP41 upper, IP54 lower |
| Dimensions (H x W x D) | 230 x 130 x 175 mm (9.06 x 5.1 x 6.9 in) |
| Net Weight | 3 kg (6.6 lbs) |
| Certifications | CE, UL, CSA, C-tick, GOST, NOM 117 |
Installation Guide
Mount the drive vertically with ±10 degree tolerance and maintain specified clearances for heat sink airflow. Connect line and motor terminals with 4 mm² cable and torque to 1.4 N·m. Torque control terminals to 0.6 N·m. Verify line current does not exceed 3.5 A at 200V or 3.1 A at 240V. Confirm prospective line Isc of 5 kA is not exceeded. The integrated EMC filter meets EN 55011 class A group 1 and EN 61800-3 category C2 requirements. Apply 1% current derating per 100 m for altitudes above 1000 m.
Engineering Advantages
This compact 3 kg drive supports both asynchronous and synchronous motors with three control profiles, delivering flexibility across machine designs. The 170% overtorque for 60 seconds handles demanding load transients. Output frequency up to 599 Hz suits high-speed spindle applications. Integrated EMC filtering eliminates external filter hardware, reducing panel space and cost. The 43 dB noise level supports installation in noise-sensitive environments. Speed accuracy of ±0.01% with encoder feedback enables precise motion control.
Technical FAQs
Q1: What motor power and voltage does the ATV71H037M3 support?
A1: This drive delivers 0.37 kW (0.5 HP) motor power from a three-phase 200-240V AC supply with a 170-264V input range.
Q2: Does this model include an EMC filter?
A2: Yes, the ATV71H037M3 includes an integrated EMC filter meeting EN 55011 class A group 1 and EN 61800-3 category C2 standards.
Q3: What is the maximum output frequency?
A3: The drive supports output frequency from 0.1 to 599 Hz with switching frequency adjustable from 1 to 16 kHz.
Goşmaça spesifikasiýalar
- Göni tok bilen işleýän
- Kompakt
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...