حوّل منزلك بأحدث حلول الإلكترونيات المتعددة، من الإضاءة الذكية إلى تحسين عملياتك باستخدام نظام المراقبة Bently Nevada 3500، الذي يقدم مراقبة الاهتزاز وحالة الآلات في الوقت الحقيقي لمنع الأعطال وزيادة وقت التشغيل. جميعها مصممة لجعل الحياة أسهل وأكثر أمانًا وترابطًا.
SKU:IC693CHS391
لوحة قاعدة التوسعة IC693CHS391 من جي إي فانك
Manufacturer: General Electric
Product No.: IC693CHS391
Product Type: لوحة قاعدة التوسيع
Product Origin: USA
Payment:T/T, Western Union
Weight: 820g
Shipping port: Xiamen
Warranty: 12 months
مشاركة
- توصيل سريع
- دعم على مدار الساعة
- ضمان الجودة
Description
Product Overview
The IC693CHS391 is a 10-slot Modular CPU Baseplate engineered by GE Fanuc for the legacy Series 90-30 programmable logic controller (PLC) platform. Serving as the primary master backplane, this structural chassis houses the internal electronic communication bus, distributed power lines, and dedicated slots required to link modular CPUs, specialized option coprocessors, and high-density I/O modules into a single, cohesive automation node. Featuring a robust, lightweight panel-mount frame with a net weight of approximately 0.82 kg, this rack ensures stable mechanical support and electrical ground connectivity for all nested automation hardware.
Key Advantages
- Maximized Module Footprint: Provides 1 dedicated CPU/specialty module slot (Slot 1) and 9 multi-purpose I/O or option slots (Slots 2-10) to accommodate expansive automation systems.
- Dedicated Power Slotting: The leftmost power supply receiver is separate from the formal slot count, maximizing available physical space for field wiring modules.
- Flexible Bus Expansion: Outfitted with a right-hand 25-pin female connector port capable of daisy-chaining up to 4 or 7 expansion/remote baseplates over a maximum distance of 700 feet.
- Optimized Physical Construction: Engineered with a compact layout that minimizes cabinet footprint while its 0.82 kg lightweight open-enclosure design facilitates simple installation, passive convection cooling, and rapid hardware module swapping.
Technical Specifications
| Model Designation | IC693CHS391 |
| Product Series / Brand | Series 90-30 PLC (GE Fanuc) |
| Baseplate Classification | Modular CPU / Main Master Rack Baseplate |
| Total Logical Slots | 10 Slots (1 Dedicated CPU Slot | 9 Standard I/O Slots) |
| Unnumbered Slots | 1 x Power Supply Module Slot (Leftmost Position) |
| Expansion Bus Interface | 25-Pin Female D-Sub Connector (Rightmost Position) |
| Default Rack Address | Rack Number 0 (System Master Node) |
| Internal Circuit Ratings | 5 VDC Bus Voltage | 420 mA Internal Circuit Draw Current |
| Physical Weight | Net Weight: 0.82 kg (Approx. 1.8 lbs) |
| Mounting Orientation | Panel Mounting Only (Vertical or Horizontal Plane Configurations) |
Quick Installation Tips
- Node Address Rule: As the primary CPU master baseplate, this chassis is assigned to Rack Number 0 by default. Only one (1) CPU baseplate can exist in a single system control group.
- Slot Layout Constraints: Always place your primary power supply in the leftmost slot. Secure the CPU or complex modules (e.g., FIP Bus Remote I/O Scanner) strictly into Slot 1, as it is uniquely wired for processing cards. Slots 2 through 10 are reserved for discrete/analog I/O and standard options.
- Bus Interconnection: Use high-grade shielded matching cables under 700 feet long when extending connections via the 25-pin female D-sub connector to remote or expansion baseplates.
- Environmental Shielding: Mount the 0.82 kg open chassis securely using screws and washers on a flat metal panel inside an enclosure. Ensure the backplane is properly grounded and kept isolated from airborne dust, water mist, and corrosive chemical agents.
Technical FAQs
Q1: Why is the power supply module slot excluded from the total 10-slot count?
A1: GE Fanuc separates the power slot to ensure users get 10 true operational slots for control components. The power supply sits on the far left, directly feeding the 5 VDC internal power lines without occupying a system address channel.
Q2: Can this baseplate run as a standalone expansion rack without a CPU?
A2: No. The IC693CHS391 is specifically designed as the master CPU baseplate (Rack 0). For sub-racks without a local processor, separate expansion or remote I/O baseplates must be used and connected via the 25-pin bus port.
Q3: How many expansion racks can be daisy-chained to this master chassis?
A3: Depending on the specific model of the CPU module installed in Slot 1, the backplane bus can support a maximum of either 4 or 7 additional downstream expansion baseplates.
المواصفات الإضافية
سكالر (V/f)
فيكتور
يعمل بالكهرباء التيار المتردد (AC)
دليل الشراء
- تأكد من الطراز الدقيق، ورقم القطعة، والمواصفات قبل الطلب.
- تحقق من التوافق مع آلتك الحالية أو أنظمة التحكم.
- تواصل عبر sale@etowonauto.com أو +8617859788089 للحصول على المساعدة الفنية.
- راجع خيارات التسليم، وأوقات الانتظار، ومتطلبات الشحن.
- اتبع تعليمات الصانع وأفضل الممارسات أثناء التركيب.
الشحن والإرجاع
يتم عادةً شحن العناصر المتوفرة في المخزون في نفس يوم العمل. بالنسبة للمنتجات غير المتوفرة حالياً في المخزون، قد تختلف أوقات الشحن بناءً على التوفر. الشحن الدولي متاح، ويتم حساب تكاليف الشحن وفقًا للوجهة والوزن واختيار الناقل.
يتم قبول الإرجاع خلال 30 يومًا من الاستلام، بشرط أن تكون العناصر غير مستخدمة وفي حالتها الأصلية. تكاليف شحن الإرجاع هي مسؤولية العميل. يرجى الاتصال بنا قبل إرجاع أي عنصر للحصول على تصريح الإرجاع.
لمزيد من التفاصيل، يرجى مراجعة سياسة الشحن والإرجاع.

وحدة مراقبة درجة الحرارة 3500/61-05-CN | بنتلي نيفادا
وحدة تي دي آي 3500/22-01-02-سي إن بينتلي نيفادا
بنتلي نيفادا 3500/42-04-00 | جهاز رصد الزلازل
-
شحن سريع
قطع الغيار الأصلية للأتمتة الصناعية متوفرة للشحن الفوري في جميع أنحاء العالم.
-
إرجاع سهل
دعم الإرجاع لمدة 30 يومًا مع ضمان لمدة 12 شهرًا لحماية موثوقة بعد البيع.
-
دعم على مدار الساعة
دعم مهني سريع الاستجابة للمساعدة في الحفاظ على عمليات مستقرة وفعالة.
-
أصلي وحقيقي
100% أصلي، مصدره مباشرة من مصنعي الأتمتة الصناعية الموثوقين.
الدليل الفني ودليل الشراء
-
Why Hybrid AB PLC + ABB DCS Beat Single-Vendor Systems?
This article examines how hybrid integration of Allen‑Bradley PLC and ABB DCS overcomes single-vendor limitations in ...
-
PLC, DCS, or TSI: Which Controls Fit Your Plant?
This article reviews five trusted industrial control system combinations from Allen‑Bradley, ABB, Emerson, GE Fanuc, ...
-
How to Integrate GE Fanuc PLC with ABB DCS Using OPC UA?
This article delivers a practical guide for integrating GE Fanuc PLCs with ABB DCS using OPC UA in Industry 4.0 envir...
-
Can DCS-PLC Integration Cut Chemical Plant Downtime by 37%?
This technical article examines how strategic integration of Emerson DeltaV DCS and Allen-Bradley PLC resolves instab...
-
How to Source Genuine PLC/DCS Spares and Avoid Counterfeit Risks?
Global manufacturers face rising counterfeit PLC and DCS modules that cause signal deviations, unplanned failures, an...
-
Can Bently Nevada-PLC-DCS Integration End Unplanned Downtime?
This article examines how integrating Bently Nevada TSI sensors with PLC and DCS systems resolves industrial data fra...