Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:VFD022EL21A
VFD022EL21A Delta Electronics 11A Single-Phase Micro Drive
Manufacturer: Delta
Product No.: VFD022EL21A
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1400g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Description
Product Overview
The Delta Electronics VFD022EL21A is a commercial-grade, multi-functional micro AC inverter from the high-reliability VFD-EL series. Engineered to support standard induction motor assets up to 3 Horsepower (2.2 kW), this compact variable frequency drive features a convenient single-phase 230V input line configuration that outputs a balanced 3-phase current rated at 11 Amps. Optimized for tight panel footprints and streamlined installation, it incorporates a built-in digital operating keypad, side-by-side DIN-rail mounting capabilities, and an integrated dynamic braking chopper circuit. Relying on an advanced open-loop V/Hz scalar control module, the VFD022EL21A provides exceptionally smooth speed regulation and energy savings for mechanical fans, water pumps, conveyor systems, and dedicated packaging machines.
Core Technical Advantages
Stable Volts-per-Hertz Scalar Control
Operating on a standard open-loop V/Hz tracking profile, the drive supplies reliable voltage-to-frequency proportional output curves. This makes it an exceptionally efficient option for variable and constant torque loads that do not require complex, encoder-based closed-loop response networks.
Internal Dynamic Braking Chopper
A factory-integrated dynamic braking transistor comes standard on the internal power card. When connected to a compatible external power dissipation resistor, the drive effectively prevents overvoltage faults caused by high-inertia regenerative loads during aggressive deceleration cycles.
Onboard Digital User Interface
The drive features factory-integrated operator controls positioned directly on its front panel. This clear digital setup eliminates the need to source standalone keypads, allowing plant operators to quickly adjust frequency parameters, map digital I/O lines, and review active fault logs.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Electronics |
| Model Number | VFD022EL21A |
| Power Specifications | 3 HP / 2.2 kW (Constant Torque capacity) |
| Main Input Power | 1-Phase, 200V to 240V AC incoming spectrum |
| Output Amperage | 11 Amps maximum continuous output current |
| Peak Output Frequency | 0.1 to 600 Hz customizable operation bounds |
| Mechanical Classification | Frame Size B | IP20 ingress protection rating |
| Chassis Dimensions | 6.85 x 3.94 x 5.35 Inches (H x W x D) |
| Net Weight | 1.4 kg (3.09 lbs) nominal physical weight |
Installation and Maintenance
Frame Size B Spacing Clearances
The Frame B chassis features standard physical constraints of 6.85 x 3.94 x 5.35 inches and carries a net weight of approximately 1.4 kg (3.09 lbs). This compact footprint allows for easy DIN-rail attachment. Ensure you leave adequate open space above and below the cooling heatsinks to allow proper air passage inside the enclosure.
Single-Phase Input Power Termination
The incoming single-phase 200–240 V AC supply utility wires should be terminated exclusively onto the primary L1 and L2 terminals. Do not attach any incoming hot source wires onto terminals U, V, or W, as these are dedicated output vectors for supplying balanced 3-phase current to the induction motor.
Environmental Ingress Considerations
This micro inverter features a stock IP20 open-chassis rating and lacks environmental moisture seals. For machine configurations located in zones exposed to oil residue, conductive metal dust, or water spray, ensure the drive is installed inside a sealed secondary electrical cabinet (NEMA 12 or IP54).
Engineering Advantages
High-Frequency Processing Window
Capable of tracking and maintaining output currents up to a high frequency limit of 600 Hz, the VFD022EL21A easily manages specialized high-speed machinery assets, such as wood woodworking spindles, chemical mixers, and processing separators.
Programmable DC Injection Braking
The integrated DC injection control logic enables developers to apply a stationary DC magnetic field across the motor windings. This function provides holding torque to prevent mechanical drift on ventilation fans or heavily loaded conveyor setups prior to active motor acceleration.
Dense Side-by-Side Installation
The streamlined physical layout of the VFD-EL platform allows for adjacent, high-density side-by-side drive clusters on a single control rail. This layout significantly reduces required cabinet enclosure sizes and associated infrastructure costs.
Technical FAQs
Q1: Can I operate the VFD022EL21A drive by feeding it a standard 3-phase AC input?
A1: No, the VFD022EL21A is engineered exclusively for a single-phase 200–240 V AC input line. The internal rectifier circuit converts this single-phase source to provide a standard 3-phase variable frequency output for 3-phase induction motors.
Q2: What is the primary difference between Delta's VFD-E and VFD-EL drive series?
A2: The VFD-EL family is a cost-effective micro drive line that utilizes V/Hz scalar control alongside a built-in digital operating interface. The VFD-E series is a modular vector micro drive platform that provides open-loop vector tracking and supports plug-in expansion cards.
Q3: Is the dynamic braking resistor pre-installed inside the Frame B chassis?
A3: The unit contains the internal dynamic braking control circuit (chopper), but the heavy-duty power resistor itself is an external accessory. To enable active dynamic braking on high-inertia loads, you must size and install an external braking resistor separately.
Commercial Contact Email: sale@etowonauto.com
Goşmaça spesifikasiýalar
- Gara
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
