Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1734-IM4
POINT I/O Digital AC Input Module Allen-Bradley 1734-IM4
Manufacturer: Allen-Bradley
Product No.: 1734-IM4
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 30g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1734-IM4 is a POINT I/O 1734 series digital AC input module with 4 input channels labeled 0 to 3. It operates at 220V AC nominal with an on-state voltage range of 159 to 264V AC. Weighing approximately 30.9 g (1.09 oz), this open-style module mounts on a DIN rail and requires the mounting base keyswitch in position 8.
Technical Configuration
This module provides 4 non-isolated sink inputs in one group with individual status indicators per channel. Each input has a 20 ms hardware filter plus a programmable digital filter from 1 to 65.535 ms in 1 ms increments. Status indicators show network state, module state, and individual input states. The module accepts 22 to 14 AWG solid or stranded copper wire and measures 2.21 x 0.47 x 2.97 inches.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IM4 |
| Series | POINT I/O |
| Module Type | Digital AC Input Module |
| Inputs | 4 (1 group of 4), non-isolated sink |
| Input Voltage | 220V AC nominal at 60 Hz |
| On-State Voltage Range | 159-264V AC |
| On-State Current | 6.2 mA @ 159V AC; 10.2 mA @ 264V AC |
| Delay Time (ON-OFF/OFF-ON) | 20 ms hardware filter + 1-65.535 ms programmable digital filter |
| Nominal Input Impedance | 22.3 kΩ |
| POINTBus Current | 75 mA at 5V DC |
| Power Dissipation | Max 0.80 W at 264V AC |
| Thermal Dissipation | Max 2.73 BTU/hour at 264V AC |
| Isolation Voltage | 240V continuous (field to system) |
| Key Switch Position | 8 |
| Wire Size | 22-14 AWG copper |
| Dimensions | 2.21 x 0.47 x 2.97 in |
| Weight | 30.9 g (1.09 oz) |
Installation Guide
Rotate the mounting base keyswitch to position 8 before installing the module. Mount on a DIN rail and wire field connections with 22 to 14 AWG solid or stranded copper wire. Verify the AC supply delivers 220V AC at 60 Hz within the 159-264V AC on-state range. Configure the programmable digital filter between 1 and 65.535 ms according to application noise requirements. Confirm 240V continuous isolation between field side and system before energizing.
Engineering Advantages
This module provides 4 AC input channels in a compact 30.9 g package, conserving panel space in distributed I/O architectures. The programmable digital filter from 1 to 65.535 ms allows noise rejection tuning without external hardware. Individual status indicators per channel accelerate fault diagnosis. The 22.3 kΩ input impedance and 240V continuous isolation protect the POINT bus from field transients. The wide 159-264V AC range tolerates supply variations in industrial power systems.
Technical FAQs
Q1: How many inputs does the 1734-IM4 provide?
A1: This module provides 4 non-isolated sink inputs in one group, labeled 0 to 3, each with an individual status indicator.
Q2: What filter options are available on this module?
A2: Inputs include a 20 ms hardware filter plus a programmable digital filter from 1 to 65.535 ms in 1 ms increments.
Q3: What isolation does the 1734-IM4 provide?
A3: The module offers 240V continuous isolation between the field side and the system for protection against hazardous voltages.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
