Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:MTL5018
MTL Instruments | MTL5018 Dual Channel Controller
Manufacturer: MTL
Product No.: MTL5018
Product Type: Detector Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
MTL5018 Dual Channel Relay Interface
The MTL5018 from MTL Instruments provides dual-channel control of safe-area loads from hazardous area switches and proximity detectors. This advanced interface features two independent relay outputs with comprehensive safety features including line fault detection and phase reversal control for each channel.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5018
- Product Type: Dual Channel Relay Interface
- Channels: Two independent channels
- Outputs: Two changeover relays
- Response Time: 10ms maximum
- Input Standard: NAMUR/DIN 19234
Hazardous Area Certification
- Switch Location: Zone 0, IIC, T6 hazardous area
- Detector Location: Zone 0, IIC, T4-T6 with certification
- Division Rating: Division 1, Group A hazardous location
- The MTL5018 maintains intrinsic safety for both channels
Input Specifications
- Sensor Voltage: 7 to 9V from 1kΩ ±10% source per channel
- Normal Phase: Output energizes if Iin >2.1mA or Rin <2kΩ
- Reverse Phase: Output de-energizes under same conditions
- Hysteresis: 200µA typical per channel for stable switching
- Phase Reversal: Independent for each channel, user-selectable
Relay Output Characteristics
- Relay Type: Two single-pole changeover contacts
- Contact Rating AC: 250V AC, 2A, cosø >0.7
- Contact Rating DC: 40V DC, 2A, resistive load
- Response Time: 10ms maximum per channel
- Note: Reactive loads require adequate suppression
Line Fault Detection (LFD)
- LFD Mode: User-selectable via top switches for each channel
- Open-circuit Alarm: On if Iin <100µA, Off if Iin >250µA
- Short-circuit Alarm: On if Rin <100Ω, Off if Rin >360Ω
- Fault Response: Detected line fault de-energizes the relay
- Contact Input: Requires 500Ω-1kΩ series and 20kΩ-25kΩ parallel resistors
Terminal Configuration
- Channel 1 Input: Terminal 1 (Input –ve), Terminal 2 (Input +ve)
- Channel 2 Input: Terminal 4 (Input –ve), Terminal 5 (Input +ve)
- Earth Leakage: Terminal 3 (Ch 1), Terminal 6 (Ch 2) for detection
- Channel 1 Output: Terminal 10 (NC), 11 (Common), 12 (NO)
- Channel 2 Output: Terminal 7 (NC), 8 (Common), 9 (NO)
- Power Supply: Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)
Power Requirements
- Current Consumption: 60mA at 24V maximum
- Power Dissipation: 1.4W at 24V maximum
- Maximum Dissipation: 1.5W at 35V
- Isolation: 250V AC or DC between all circuits
Safety Parameters
- Safety Voltage: 10.5V maximum per channel
- Internal Resistance: 800Ω per channel
- Safety Current: 14mA maximum per channel
- Maximum Voltage: Um = 250V rms or DC
Frequently Asked Questions
-
How many loads can the MTL5018 control?
It can control two independent safe-area loads from two hazardous area inputs. -
Are the channels independently configurable?
Yes, each channel has independent phase reversal and line fault detection. -
How does line fault detection work?
It detects open circuits (<100µA) and short circuits (<100Ω) with individual channel indication. -
What is the relay response time?
The relays respond within 10ms maximum for each channel.
For pricing and technical support, please contact sale@etowonauto.com
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...