Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:KCD2-SOT-EX1.LB
KCD2-SOT-Ex1.LB Isolated Barrier | Pepperl+Fuchs
Manufacturer: Pepperl+Fuchs
Product No.: KCD2-SOT-EX1.LB
Product Type: Switch Amplifier
Product Origin: DE
Payment:T/T, Western Union
Weight: 100g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Pepperl+Fuchs KCD2-SOT-Ex1.LB Switch Amplifier
The Pepperl+Fuchs KCD2-SOT-Ex1.LB is an isolated switch amplifier for hazardous areas. This 1-channel barrier interfaces NAMUR sensors with control systems. It provides two transistor outputs for signal splitting applications. The Pepperl+Fuchs KCD2-SOT-Ex1.LB offers safe operation in explosive atmospheres with ATEX certification.
Product Identification
- Manufacturer: Pepperl+Fuchs
- Model Number: KCD2-SOT-Ex1.LB switch amplifier
- Product Type: 1-Channel Isolated Barrier
- Primary Function: Digital input signal conditioning
- Safety Rating: SIL 2, SC 3 per IEC/EN 61508
- Certification: ATEX certified for hazardous areas
- Housing Width: 12.5 mm compact design
Power Supply Specifications
- Supply Voltage: 24 V DC nominal (19-30 V DC range)
- Connection: Power Rail or terminals 9+, 10-
- Rated Current: 20-15 mA typical consumption
- Power Dissipation: ≤ 700 mW maximum
- Ripple Tolerance: ≤ 10 % input ripple
Input Specifications
- Signal Type: Digital Input (NAMUR or dry contact)
- Connection: Terminals 1+, 2- (field side)
- NAMUR Values: 10 V DC / 8 mA per EN 60947-5-6
- Switching Point: 1.2-2.1 mA with 0.2 mA hysteresis
- Line Fault Detection: Breakage I ≤ 0.1 mA, short I ≥ 6.5 mA
- Pulse Requirements: Min. 100 µs pulse/pause ratio
Output Performance
- Output Channels: Two passive transistor outputs
- Connection: Output I: terminals 5,6; Output II: terminals 7,8
- Rated Voltage: 30 V DC maximum
- Rated Current: 50 mA per output
- Response Time: ≤ 200 µs fast switching
- 1-Signal Level: (External voltage) - 3V max at 50 mA
- 0-Signal Level: Blocked output (≤10 µA leakage)
- Switching Frequency: ≤ 5 kHz maximum
Safety & Isolation
- Safety Level: SIL 2, Systematic Capability SC 3
- Galvanic Isolation: Reinforced insulation 300 Veff
- Isolation Ratings: Input/Output: 300 Veff reinforced
- Hazardous Area: ATEX certified [Ex ia Ga] IIC
- Protection Degree: IP20 for indoor use
Configuration & Display
- Configuration: DIP switch settings
- Display Elements: LED status indicators
- Labeling: Front space for identification
- Operating Mode: Reversible operation possible
- Signal Splitting: 1 input to 2 outputs capability
Environmental Specifications
- Temperature Range: -20°C to +70°C standard
- Extended Range: Up to 70°C with derating
- Mounting: 35 mm DIN rail per EN 60715
- Dimensions: 12.5 x 119 x 114 mm (WxHxD)
- Weight: Approx. 100 grams
Certifications & Compliance
- ATEX Certificate: BASEEFA 13 ATEX 0080
- Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC
- EMC Directive: 2014/30/EU, EN 61326-1:2013
- Safety Standards: IEC 61010-1:2010 compliance
Installation Guidelines
- Mount on 35 mm DIN rail in appropriate enclosure
- Connect 24V DC power via Power Rail or terminals
- Wire NAMUR sensor or dry contact to input terminals
- Connect outputs to control system inputs
- Configure DIP switches for required operation mode
- Verify proper grounding for hazardous area installation
Frequently Asked Questions (FAQ)
What is the main purpose of this switch amplifier?
The Pepperl+Fuchs KCD2-SOT-Ex1.LB safely interfaces hazardous area sensors with control systems.
Can I use this with standard mechanical contacts?
Yes, it accepts both NAMUR sensors and dry contact inputs.
What does "signal splitter" function mean?
It can take one input signal and provide two identical output signals.
How does line fault detection work?
It detects open circuits (<0.1 mA) and short circuits (>6.5 mA) in field wiring.
What hazardous area classifications does it support?
ATEX Zone 0/1 for gas and Zone 20/21 for dust explosive atmospheres.
What configuration options are available?
DIP switches allow setting operating mode, output configuration, and fault behavior.
For technical specifications or to order the KCD2-SOT-Ex1.LB, email sale@etowonauto.com.
Content provided by Etowon Auto.
Goşmaça spesifikasiýalar
- Gök
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
