Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CC-PDOD51
Honeywell CC-PDOD51 32-Channel Digital Output
Manufacturer: Honeywell
Product No.: CC-PDOD51
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 800g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Honeywell CC-PDOD51: 32-Channel Sink Digital Output
The Honeywell CC-PDOD51 delivers high-density digital switching for industrial applications.
Output Specifications
- Brand: Honeywell
- Model: CC-PDOD51
- Type: Series C Digital Output Module
- Channels: 32 digital outputs
- Output Type: SINK (Open Drain)
- Load Voltage: 30 VDC maximum
- Load Current: 0.1 A per channel max
- On-State Voltage: 0 VDC at 0.1A load
- Off-State Voltage: 24 VDC typical
- Off-State Leakage: 100 µA maximum
- Turn-On/Off Time: 10 ms maximum
Isolation & Protection
- Galvanic Isolation: 1000 VAC RMS system-to-field
- Field Power: User supplied external 24V
- Bussed Output: Common return for group wiring
- Coating: Conformal coated for harsh environments
- Redundancy Gap: 0ms switchover (redundant systems)
Compatible IOTA
- IOTA Model: CC-TDOD51
- Configuration: Non Redundant
- IOTA Position: 9 (standard mounting)
Environmental Ratings
- Temperature: -40°C to +70°C operating
- Storage: -55°C to +85°C
- Humidity: 5% to 95% non-condensing
- Vibration: IEC 60068-2-6 compliant
- EMC: IEC 61000-6-2, IEC 61000-6-4
Physical Characteristics
- Weight: 0.9kg (1.98 lbs)
- Terminals: Via CC-TDOD51 IOTA
- LED Indicators: Per channel status on IOTA
- Mounting: Series C I/O rack
- Coating: Conformal coated circuit boards
Frequently Asked Questions
Q: What external power supply do I need for the CC-PDOD51?
A: The CC-PDOD51 requires a user-supplied 24V DC field power source. Connect this to the CC-TDOD51 IOTA terminals. The module isolates this field power from the system backplane.
Q: Can I drive 24V DC relays with the 0.1A output?
A: Yes. Most industrial relays draw 20-50mA at 24V. The CC-PDOD51 easily drives them. Check your specific relay coil current stays under 100mA.
Q: What does 0ms gap mean for redundancy?
A: In redundant configurations, the CC-PDOD51 switches outputs with zero interruption. The backup takes over immediately with no current gap to field devices.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
