Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:A6500-UM
Emerson A6500-UM Universal Measurement Card for Machinery Monitoring
Manufacturer: Emerson
Product No.: A6500-UM
Product Type: Universal Measurement Card
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Emerson A6500-UM Universal Measurement Card
The A6500-UM from Emerson is a versatile dual-channel measurement module for the AMS 6500 machinery protection system. This single-slot card accepts multiple sensor types for comprehensive machine monitoring.
Compact Design and Key Features
- Two-channel 3U module saves 50% cabinet space versus traditional 6U cards.
- Fully compliant with API 670 machinery protection standards.
- Features hot-swappable design for easy maintenance without system downtime.
- Supports remote selection of limit multiply and trip bypass functions.
- Includes 5 digital inputs and 6 digital outputs for flexible system integration.
Multi-Sensor Input Specifications
- Brand & Model: Emerson A6500-UM Universal Measurement Card.
- Compatible Sensors: Eddy-current, piezoelectric (accel/velometer), seismic, LF vibration, Hall-effect, LVDT, and dynamic pressure.
- Eddy Current Input: -1 to -22 V, 0-18,750 Hz, -23.25/-26.0 VDC supply, ±1% accuracy.
- Piezoelectric Input: +1 to +23 V, 0-18,750 Hz, 0-8 mA constant current supply.
- Seismic Input: -10 to +15 V, 0-2,000 Hz, 0-8 mA lifting current supply.
- LF Vibration Input: -11 to +11 V, 0-1,000 Hz, ±15 VDC supply.
Measurement Functions and Outputs
- Measurement Modes: Shaft vibration, case vibration, position, speed/key, dynamic pressure.
- Current Outputs: Two 0/4-20 mA channels, ±1% accuracy, load <500 Ω.
- Digital Outputs: Six solid-state relays (normally open), 19-32 VDC, 100 mA max load.
- Pulse Outputs: Two opto-decoupled outputs, 0-2,000 Hz, 30 mA max load.
- Raw Signal Outputs: One per sensor input, non-reactive, ±1% accuracy.
- Communication: Internal RS-485 to Modbus RTU/TCP via A6500-CC Com Card.
Environmental and Physical Specifications
- Operating Temperature: -20°C to 70°C (-4°F to 158°F) with cooling; -20°C to 55°C (-4°F to 131°F) without.
- Storage Temperature: -40°C to +85°C (-40°F to 185°F).
- Humidity: 5% to 95% RH, non-condensing.
- Vibration Resistance: IEC 60068-2-6 (0.15mm at 10-55 Hz, 20m/s² at 55-150 Hz).
- Power Supply: 24 VDC, maximum 6W consumption.
- Dimensions: 3RU height, 6HP width, 100 x 160mm PCB.
- Weight: Approximately 200g (0.44 lbs) excluding packaging.
Certifications and Safety Approvals
- Safety Standard: IEC 61010-1 compliant.
- Hazardous Area: ATEX/IECEx II 3G Ex nA nC IIC Gc, T4.
- North America: CSA Class I Div 2, Groups A,B,C,D; UL 61010-1 listed.
- International: CE, EAC, CCC, CCOE PESO India, and DNV GL marine certifications.
- Safety Integrity: SC 2 (SIL 2 Capable) per IEC 61508.
Frequently Asked Questions
-
Q: What types of measurements can the A6500-UM card perform?
A: It performs shaft vibration, case vibration (displacement/velocity/acceleration), position (distance, rod drop, eccentricity), speed/key, and dynamic pressure measurements. -
Q: What communication protocols does this card support?
A: It communicates via internal RS-485 bus to the A6500-CC Com Card, which provides Modbus RTU and Modbus TCP/IP outputs for connection to control systems. -
Q: Is this card suitable for use in hazardous areas?
A: Yes, it carries multiple hazardous area certifications including ATEX, IECEx, CSA, and CCC-Ex for use in Class I Division 2/Zone 2 areas with appropriate installation.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...