Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:VFD220VL43A
Delta VFD220VL43A Elevator Drive PG Close Loop High Torque
Manufacturer: Delta
Product No.: VFD220VL43A
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 11500g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Delta VFD220VL43A Elevator Drive
The Delta VFD220VL43A is a high-performance AC drive. It is part of the VFD-VL series. This drive is designed for elevator applications. It controls both PM (Permanent Magnet) and IM (Induction) motors. The drive offers high safety and reliability. It features advanced elevator-specific functions.
Key Features and Benefits
- Elevator-Optimized: Designed specifically for elevator traction systems.
- High Torque: Delivers 150% torque at 0.5Hz and 200% at 0Hz for smooth starts.
- Built-In Safety: Integrated brake chopper and comprehensive self-protection features.
- Flexible Control: Supports V/F, Sensorless Vector, and PG-based FOC/Torque control.
- Strong Communication: Built-in RS-485 (MODBUS) for easy system integration.
Complete Technical Specifications
- Manufacturer: Delta
- Model: VFD220VL43A
- Series: VFD-VL (Elevator Drive Series)
- Product Name: AC Drive / Elevator Drive
- Rated Power: 22 kW / 30 HP
- Voltage Class: 440V, 3-Phase
- Output Current: 47 A
- Output Frequency: 0.00 to 120 Hz
- Control Modes: V/F, Sensorless Vector, V/F-PG, FOC-PG, Torque-PG, FOC-PG (for PM Motor)
- PG Close Loop: Yes (Encoder feedback supported)
- Start-up Torque: 150% at 0.5 Hz, 200% at 0.0 Hz (with PG)
- Overload Capacity: 150% for 1 minute, 200% for 2 seconds
- Braking Chopper: In-Built
- Communication: RS-485 (MODBUS protocol)
- PID/PLC Function: No
- Application: Elevator for PM and IM Motors
- RoHS Compliance: Yes
- Weight: 11.5 kg
- Dimensions (WxHxD): Refer to official manual for exact size.
- Cooling Method: Fan cooling
- Protection Features: Overcurrent, overvoltage, undervoltage, overload, overheat, short circuit protection.
- Ambient Temperature: -10°C to 50°C for operation, -20°C to 60°C for storage.
- Humidity: 0% to 90% RH (non-condensing).
Installation and Wiring Notes
- Mount in a well-ventilated, clean, and dry cabinet.
- Ensure proper clearance around the drive for airflow.
- Follow local electrical codes for wiring and safety disconnects.
- Use shielded cables for encoder and communication lines.
- Connect the built-in brake chopper to an appropriate braking resistor.
- Ground the drive chassis properly for safety and noise immunity.
Compatibility and Integration
- Designed to control standard 3-phase asynchronous (IM) and permanent magnet (PM) motors.
- Integrates with elevator controllers via digital I/O and RS-485 MODBUS.
- Compatible with various incremental encoders for speed/position feedback.
Package and Support
- Package Includes: 1 x VFD220VL43A Drive Unit, 1 x User Manual, Optional keypad may be included separately.
- Warranty: Standard manufacturer warranty applies (typically 12-18 months, confirm with supplier).
- Shipping: Available via major carriers (FedEx, DHL, UPS).
Typical Applications
- Traction control for passenger and freight elevators.
- Modernization and retrofit of existing elevator systems.
- Control of hoisting machinery with PM or IM motors.
FAQ and Troubleshooting
Q: Can this drive run a standard induction motor without an encoder?
- A: Yes. You can use it in V/F or Sensorless Vector control mode without a PG (encoder).
Q: Is an external braking resistor required?
- A: The drive has a built-in brake chopper, but you must connect an external braking resistor to it for energy dissipation during rapid stops.
Q: What is the first step after installing the drive?
- A: Always perform motor parameter auto-tuning (with the motor disconnected from the load) for best performance in vector control modes.
Goşmaça spesifikasiýalar
- Gara
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Näme üçin PLC we DCS ulgamlaryňyz üçin 99,8% ygtybarlylyk hayatähmiýetli?
Bu makalada berk barlanylan serhetara dolandyryş şaýlarynyň senagat awtomatizasiýa amallaryny nädip durnuklaşdyrýandy...
-
Bilelikdäki dolandyryşy optimizasiýa etmek önümçilikde OEE-ni 20% ýokarlandyryp biler mi?
Adaty biri-birinden üzňe PLC we DCS ulgamlary önümçilik tapgyrlarynyň arasynda günde 10–18% boş durluşa sebäp bolýar....
-
Hierarhiýaly dolandyryş zawodynyň OEE-sini 64 %-den 82 %-e nähili ýokarlandyrýar?
Bu makalada hierarhiki bulut-çet hyzmatdaşlyk dolandyryşynyň böleklenen senagat arhitekturalarynyň ornuny nädip tutýa...
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
