Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:VFD022EL21W
Delta VFD EL-W 2 Horsepower 230V Motor Drive VFD022EL21W
Manufacturer: Delta
Product No.: VFD022EL21W
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The VFD022EL21W(-1) is an ultra-compact, cost-effective micro-type AC motor drive from Delta’s streamlined VFD EL-W Series. Engineered specifically to optimize space and reduce costs in low-horsepower applications, this 2 HP (2.2 kW) variable frequency inverter provides stable velocity modulation for standard automation equipment like commercial mixers, fans, pumps, and light-duty material conveyors. It operates efficiently on a standard 1-phase 230 V AC input line and delivers a steady 11 A output. Featuring a highly specialized shallow-depth housing and an incredibly lightweight structure weighing only 2.2 lbs (1.0 kg), it delivers exceptional power density for restricted panel layouts.
Core Technical Advantages
Optimized Shallow-Depth Housing
The specialized EL-W series features a modified physical geometry with a reduced depth profile of just 5.35 inches (with a total installation space envelope of 3.94 × 3.5 × 6.85 inches). This compact layout lets system builders mount the drive inside shallow electrical enclosures where standard inverters cannot fit.
High-Density Side-by-Side Mounting
The optimized thermal dissipation architecture allows high-density side-by-side configurations on standard DIN rails. This structural arrangement cuts cabinet space requirements dramatically while providing high power output from a single-phase supply line.
Efficient Scalar Performance
Supporting a maximum adjustable output frequency up to 400 Hz, the open-loop V/Hz (Scalar) control system ensures accurate torque compensation and smooth speed curves for standard induction motors and high-speed processing machinery.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Products (VFD EL-W Series) |
| Model Number | VFD022EL21W(-1) |
| Motor Power Rating | 2.0 HP / 2.2 kW |
| Rated Output Amps | 11 Amps |
| Nominal Input VAC | 230 Volts AC (Range: 200–240 V) |
| Input Phase | 1-Phase |
| Device Net Weight | 2.2 lbs (1.0 kg) |
| Enclosure Rating | IP20 |
| Dimensions (W × H × D) | 3.94 × 3.5 × 6.85 Inches |
Installation and Maintenance
Enclosure Thermal Layouts
The IP20 open-type chassis must sit within a clean, dry, well-ventilated cabinet environment free from oil mist, moisture, and conductive metal shavings. Keep a minimum vertical clearance of 50 mm above and below the module to allow heat from the cooling vents to escape properly.
Power Integration Rules
Terminate incoming single-phase mains wires exclusively to input terminals L1 and L2. Wire the motor leads directly to terminals U, V, and W. Never introduce utility AC lines to the U, V, W outputs, or the internal power semiconductor components will suffer irreversible catastrophic failure.
Braking Configuration
For operations involving rapid deceleration steps, fine-tune the internal deceleration parameters ($DEC$) to prevent regenerative energy from creating an overvoltage spike. Ensure proper line filtering is applied to maintain compliance with local industrial EMC guidelines.
Engineering Advantages
Onboard User Controls
The built-in human-machine interface includes a clear digital parameter screen and localized control buttons. This allows plant electricians to modify speed curves, monitor running amperage, and pull historical fault logs directly on the shop floor without secondary service computers.
Streamlined V/Hz Regulation
By optimizing high-demand open-loop scalar algorithms, this drive offers automatic torque boosting, multi-step operations, and integrated electronic thermal protection without the high cost overhead of advanced vector-drive systems.
Active Circuit Defense
Onboard firmware elements actively check for overcurrent, overvoltage, low input voltage, and ground leaks. If a fault is found, the inverter trips instantly to protect both the internal electronic components and the motor winding insulation.
Technical FAQs
Q1: What is the main design difference between the standard VFD-EL series and this EL-W variant?
A1: The EL-W variant features a modified structural layout that optimizes installation dimensions for shallower enclosures. It focuses on core open-loop application requirements, offering a lighter weight of 2.2 lbs and a lower cost framework for highly competitive automation tasks.
Q2: Can this single-phase drive be run on a 3-phase AC input supply?
A2: No. This unit is strictly rated for 1-phase 230 V AC input line connections. Attempting to run it on 3-phase lines can lead to erratic voltage monitoring behavior or unbalanced thermal stress on the input bridge rectifier circuits.
Q3: How do I avoid acceleration stall faults when running heavy conveyor loads?
A3: If the drive trips on overcurrent or struggles at startup, increase the acceleration time parameter ($ACC$) to give the drive more time to ramp up, or fine-tune the manual torque boost configuration to supply more voltage at low speeds.
Goşmaça spesifikasiýalar
- Gara
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
