Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:AO810V2
AO810V2 ABB S800 Analog Output | 14-Bit 600m Cable Length
Manufacturer: ABB
Product No.: AO810V2
Product Type: Analog Output Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 180g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The ABB AO810V2 Analog Output Module delivers 8 channels of 0-20 mA or 4-20 mA signals for precise actuator and valve control. Part of the S800 I/O family, this module provides 14-bit resolution with groupwise isolation from ground. It supports field cable runs up to 600 meters, making it ideal for distributed process automation applications.
Core Functionality
The AO810V2 converts digital setpoints from the controller into analog current signals. Each output is short-circuit proof with current limiting protection. The module supports under/over range capability of ±15%, allowing extended control margins. Output load capacity varies by supply configuration: ≤500 Ω when powered from L1+ only, or 250-850 Ω with L2+ connected. The update cycle time is ≤2 ms, ensuring responsive control loops.
Technical Specifications
| Parameter | Value |
| Model Number | AO810V2 |
| Type | Analog Output |
| Signal Range | 0-20 mA / 4-20 mA |
| Channels | 8 |
| Resolution | 14 bit |
| Isolation | Groupwise isolated from ground |
| Under/Over Range | ±15% |
| Output Load (L1+ only) | ≤500 Ω |
| Output Load (L2+ only) | 250-850 Ω |
| Accuracy Error | Max 0.1% (0-500Ω) |
| Temperature Drift | Typ 30 ppm/°C, Max 60 ppm/°C |
| Rise Time | 0.35 ms (PL=500Ω) |
| Update Cycle | ≤2 ms |
| Short Circuit Protection | Current limited output |
| Max Field Cable Length | 600 m (656 yd) |
| Rated Insulation Voltage | 50 V |
| Dielectric Test Voltage | 500 V a.c. |
| Power Dissipation | 2.3 W |
| +5V Modulebus Current | Max 70 mA |
| +24V External Current | 245 mA |
| Dimensions (W x H x D) | 45 x 119 x 102 mm (1.77 x 4.7 x 4.01 in) |
| Weight | 0.18 kg (0.4 lbs) |
Compatibility
| Parameter | Value |
| Compatible MTUs | TU810, TU812, TU814, TU830, TU833 |
| Keying Code | AE |
Installation Guide
Mount the AO810V2 in any S800 I/O slot. Verify the keying code (AE) matches the MTU before insertion. Connect field wiring to the appropriate termination unit (TU810, TU812, TU814, TU830, or TU833). Ensure the external 24Vdc supply provides at least 245 mA per module. For optimal accuracy, limit field cable length to 600 meters. When using loop-powered devices, configure the supply connection (L1+ or L2+) based on the load requirements.
Engineering Advantages
The AO810V2 delivers 14-bit resolution with ±15% over-range capability, providing precise control across the full signal span. Groupwise isolation protects the control system from ground loops and field-side faults. The short-circuit proof output ensures module survival during wiring errors. Temperature drift of just 30 ppm/°C typical maintains accuracy in varying ambient conditions. The 600-meter cable length capability supports large plant layouts without signal degradation.
Technical FAQs
Q1: What is the difference between AO810 and AO810V2?
A1: The AO810V2 is the enhanced version with improved accuracy, faster update cycle (≤2 ms vs older models), and extended load range support up to 850Ω.
Q2: Can I connect a loop-powered transmitter directly to the AO810V2?
A2: Yes. The module supports 4-20 mA loop-powered devices. Select the appropriate supply configuration (L1+ or L2+) based on your load requirements.
Q3: What does the keying code AE signify?
A3: The AE keying code ensures correct module-to-MTU pairing. It prevents inserting incompatible modules into the termination unit, protecting both module and field wiring.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...