Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1794-OB16P
Allen-Bradley 1794-OB16P Electronic Fused Output 24VDC
Manufacturer: Allen-Bradley
Product No.: 1794-OB16P
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 78g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley 1794-OB16P Flex I/O DC Fused Output Module
Allen-Bradley 1794-OB16P | Flex I/O discrete DC output module with 16 electronically fused sourcing output channels. Operates at 24V DC nominal voltage with 8.0 A total output current rating. Each channel provides electronic fusing for protection against overload conditions. Weight: approximately 78 g (2.75 oz).
Key Features
16 current sourcing outputs with electronic fusing. 24V DC nominal on-state voltage (10-31.2V DC range). 8.0 A total output current rating (500 mA per channel, 1 mA minimum). Maximum on-state voltage drop 0.5V DC. Maximum off-state leakage 0.5 mA. 50V continuous isolation voltage. Surge current 2 A for 50 ms, repeatable every 2 seconds. Output signal delay 0.5 ms (OFF-to-ON) and 1 ms (ON-to-OFF). 60 mA Flexbus current at 5V DC. 16 yellow status indicators. DIN rail mounting.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OB16P |
| Product Type | Flex I/O Digital DC Output Module |
| Outputs | 16 (Sourcing, electronically fused) |
| On-State Voltage (Nominal) | 24V DC |
| On-State Voltage (Min) | 10V DC |
| On-State Voltage (Max) | 31.2V DC |
| Output Current Rating | 8.0 A (total) |
| On-State Current (Min) | 1 mA per channel |
| On-State Current (Max) | 500 mA per channel |
| On-State Voltage Drop | 0.5V DC max |
| Off-State Leakage Current | 0.5 mA max |
| Isolation Voltage | 50V continuous |
| Surge Current | 2 A for 50 ms, repeatable every 2 s |
| Signal Delay (OFF-to-ON) | 0.5 ms |
| Signal Delay (ON-to-OFF) | 1 ms |
| Flexbus Current | 60 mA @ 5V DC |
| Power Dissipation | 5.0 W @ 31.2V DC |
| Thermal Dissipation | 17.0 BTU/hr @ 31.2V DC |
| External Power Supply | 10-31.2V DC, 5% AC ripple, 25-75 mA |
| Indicators | 16 Yellow status indicators |
| Mounting | DIN Rail |
| Wire Size | Determined by installed terminal base |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Relative Humidity | 5-95% non-condensing |
| Vibration | 5g @ 10-500 Hz |
| Operating Shock | 30 g |
| Weight | Approx. 78 g (2.75 oz) |
| UPC | 10612598179968 |
Compatible Terminal Base Units
1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK, 1794-TBN, 1794-TBNK, 1794-TBKD.
Installation Notes
Install on compatible terminal base with DIN rail attachment. Use screw clamp terminations for field wiring. Connect external DC supply of 10-31.2V DC with 5% AC ripple and 25-75 mA current. Compatible with ControlNet, DeviceNet, PROFIBUS, and EtherNet/IP communication adapters. Functions as distributed I/O for ControlLogix, CompactLogix, PLC5, and SLC500 controllers. Operate within 0°C to 55°C ambient temperature.
Engineering Advantages
Electronic fusing on each channel eliminates the need for replaceable fuses and simplifies maintenance. 16 sourcing outputs maximize channel density in a single module. High 8.0 A module rating handles demanding DC loads directly. Fast 0.5 ms OFF-to-ON response supports time-critical control applications. Wide 10-31.2V DC range accommodates supply variations. Compatible with multiple communication adapters and legacy controllers for flexible system integration.
FAQs
Q1: How many outputs does this module provide?
A1: 16 electronically fused sourcing DC outputs, 500 mA per channel.
Q2: What protection does each channel have?
A2: Each channel is electronically fused for overload protection.
Q3: What communication adapters are compatible?
A3: ControlNet, DeviceNet, PROFIBUS, and EtherNet/IP.
Goşmaça spesifikasiýalar
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...