Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1756-IM16I
Allen-Bradley 1756-IM16I 16 Channel Isolated AC Input
Manufacturer: Allen-Bradley
Product No.: 1756-IM16I
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1756-IM16I is a premium, heavy-duty 16-point isolated AC digital input module belonging to the high-performance ControlLogix automation platform. Engineered for challenging industrial environments with diverse electrical grids, this module provides complete point-to-point isolation across all 16 channels, operating within a nominal voltage category of 240 Volts AC (159 to 265 VAC range). Weighing approximately 0.30 kg (0.66 lbs), this chassis-based processor card monitors high-voltage field statuses, executes precise Change-of-State (COS) tracking, and protects the core PLC backplane from dangerous multi-phase cross-faults or erratic voltage spikes.
Core Technical Advantages
- Per-Point Individual Isolation: Features 16 completely independent isolated channel grids, permitting the simultaneous monitoring of distinct AC phases or separate field power sources on a single module without phase short-circuit risks.
- Programmable Logic Filter Times: Supports highly customizable input delay filters (selectable up to 18 ms) combined with rapid hardware response times to successfully suppress contact bounce and high-frequency line noise.
- Advanced Thermal Derating Matrix: Optimized to safely dissipate up to 5.8 Watts at 60 degrees Celsius, providing robust multi-channel configuration charts to handle continuous high-temperature field operations with maximum stability.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix System) |
| Model Part Number | 1756-IM16I (UPC 10612598171344) |
| Gross Weight | 0.30 kg (0.66 lbs) |
| Module Category | Isolated Digital AC Input Module |
| Discrete Input Count | 16 Individually Isolated Inputs (Point-to-Point Isolation) |
| Nominal Voltage Category | 240 Volts AC (50 / 60 Hz operating frequency) |
| Continuous Operating Range | 159 to 265 Volts AC (47 to 63 Hz frequency bandwidth) |
| On-State Current Threshold | 5 mA minimum at 159 VAC / 13 mA maximum at 265 VAC |
| Off-State Threshold Limits | Maximum 40 Volts AC / Maximum 2.5 mA leakage current |
| Maximum Inrush Current | 250 mA peak inrush loading capability |
| Backplane Current Requirements | 100 mA at 5 VDC / 3 mA at 24 VDC (Total Bus Power: 0.58 Watts) |
| Thermal / Power Dissipation | 5.8 Watts maximum power loss / 19.78 BTU/hour thermal dissipation |
| Compatible Terminal Housing | 36-Pin Removable Terminal Blocks (1756-TBCH or 1756-TBS6H) |
Installation & Engineering Guide
- Chassis Placement & Insertion: Ensure the primary system power supply is completely isolated before beginning installation. Align the 0.30 kg hardware frame within the selected slot guides of the 1756 ControlLogix chassis, pushing it backward firmly until the top and bottom retention clips snap completely over the structural chassis rail tabs.
- 36-Pin RTB Wiring Configurations: Terminate your 240V AC field inputs through an approved 1756-TBCH (extended clamp) or 1756-TBS6H (spring clamp) 36-pin removable terminal block. Because each channel is fully isolated, always run both the active signal line and its respective neutral return line directly to the designated channel terminal pair.
- Operating Environment Derating: Monitor your local enclosure temperature guidelines closely. When executing full system density, all 16 channels can remain ON up to 30 degrees Celsius at 265 VAC; however, if operating at 40 degrees Celsius, limit simultaneous active channels to 8 points max, or derate the operational input limit down to 242 VAC at 60 degrees Celsius with all channels active.
Technical FAQs
Q1: How is the total execution delay calculated for the 1756-IM16I AC input paths?
A1: The total turnaround delay from screw to backplane is a combination of native hardware circuit latency and user-selected filter times. Going from Off-to-On, it equals the 10 ms max hardware delay plus a selectable 1 or 2 ms filter. Going from On-to-Off, it is an 8 ms max hardware delay plus a selectable 9 or 18 ms filter block.
Q2: What is the main advantage of point-to-point isolation on this specific digital input card?
A2: Unlike standard grouped inputs that share a common return bus, per-point isolation provides a completely separate circuit for each of the 16 paths. This allows you to mix different AC voltage phases or feed signals from entirely separate safety substations into a single physical card without risk of catastrophic cross-phase failure.
Q3: Does the lightweight 0.30 kg construction of this module compromise its long-term reliability?
A3: No. At roughly 0.30 kg, its specialized compact frame is optimized to save chassis balance while providing rugged structural components that comply with high-voltage industrial insulation profiles, fully meeting standard ControlLogix ratings for mechanical shock and vibrations.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
