Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1734-IT2I
Allen-Bradley 1734-IT2I | POINT I/O Isolated TC Module
Manufacturer: Allen-Bradley
Product No.: 1734-IT2I
Product Type: Input RTD Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 36g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1734-IT2I is a POINT I/O isolated analog temperature input module with 2 differential, individually isolated thermocouple inputs. It delivers 15-bit resolution at 2.5 µV/count with a ±75 mV input voltage range. Weighing 0.08 pounds (0.036 kg), this open-style module requires no external DC power supply but installs only on the 1734-TBCJC wiring base assembly.
Technical Configuration
This module produces 8 bytes of scanner data (scanner Rx) and fault status data without consuming I/O data (scanner Tx). It supports signed integer data format with 4 temperature scales (Celsius, Fahrenheit, Kelvin, Rankine) plus 1 mV custom scale. Delta Sigma conversion ensures stable readings. Status indicators monitor network state, module state, input 0 state, and input 1 state in real time. The key switch position is 6.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IT2I |
| Series | POINT I/O |
| Module Type | Analog Temperature Input Module |
| Inputs | 2 differential, individually isolated thermocouple |
| Resolution | 15 bits at 2.5 µV/cnt |
| Input Voltage | ±75 mV |
| Voltage Rating | 24V DC |
| POINTBus Current | 175 mA at 5V DC |
| Impedance / Resistance | 100 kΩ / 1 MΩ |
| Conversion Type | Delta Sigma |
| Data Format | Signed integer |
| Temperature Scales | Celsius, Fahrenheit, Kelvin, Rankine, plus 1 mV custom scale |
| Alarms | Under-range, over-range, CJC open-wire, level (low-low, low, high, high-high) |
| Power Dissipation | Max 1 Watt |
| Thermal Dissipation | Max 3.3 BTU/hour |
| Isolation Voltage | 50V continuous |
| Keyswitch Position | 6 |
| Wiring Base | 1734-TBCJC only |
| Dimensions (H x W x D) | 2.21 x 0.47 x 2.97 in |
| Weight | 0.08 lbs (0.036 kg) |
| Operating Temperature | -20 to 55°C |
| Storage Temperature | -4 to 85°C |
| Operating Vibration | 5 g at 10-500 Hz |
| Enclosure | Open style |
Installation Guide
Rotate the keyswitch to position 6 before installing the module. Mount only on the 1734-TBCJC wiring base assembly, which provides cold junction compensation. Wire thermocouple leads observing proper polarity for differential inputs. No external DC power supply is required. Configure the desired temperature scale (Celsius, Fahrenheit, Kelvin, Rankine) or mV custom scale, then enable alarm thresholds for under-range, over-range, and CJC open-wire detection.
Engineering Advantages
This module provides individually isolated differential thermocouple inputs, preventing ground loop interference between separate sensors. The 15-bit resolution at 2.5 µV/count enables detection of small temperature changes. CJC open-wire detection alerts operators to broken thermocouple circuits before process disruption. Four level alarms (low-low, low, high, high-high) support multi-stage process protection. The 8-byte scanner data output operates independently of I/O data consumption, simplifying configuration.
Technical FAQs
Q1: What type of inputs does the 1734-IT2I provide?
A1: This module provides 2 differential, individually isolated thermocouple inputs with ±75 mV range and 15-bit resolution at 2.5 µV/count.
Q2: What wiring base is required for this module?
A2: The 1734-IT2I installs only on the 1734-TBCJC wiring base assembly, which provides cold junction compensation.
Q3: What alarms does this module support?
A3: It provides under-range, over-range, CJC open-wire detection, and four level alarms (low-low, low, high, high-high).
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...