Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:3BHT410082R0001
ABB 3BHT410082R0001 Advant Bus Extender Ethernet Module
Manufacturer: ABB
Product No.: 3BHT410082R0001
Product Type: Ethernet Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The ABB 3BHT410082R0001 is a high-performance Advant Bus Extender designed to expand the communication capabilities of Advant controller systems. Utilizing a modern Ethernet-based architecture, this module provides a reliable bridge for data exchange across industrial networks. It features a standard RJ45 connection interface and is optimized for high-speed transmission at 10/100 Mbps. Engineered for longevity, this component boasts an MTBF of over 50,000 hours, ensuring stable operation in mission-critical automation environments. The unit features a net weight of 0.35 kg (0.77 lbs), making it a lightweight yet durable solution for cabinet installation.
Technical Configuration
Advanced Networking & Connectivity
This Advant Bus Extender is built for scalability, supporting a maximum of 16 device connections per module. It requires Category 5e cabling or higher to maintain signal integrity at peak data rates. To facilitate real-time diagnostics, the front panel is equipped with integrated LED indicators for Power, Status, and Communication, allowing maintenance teams to verify network health at a glance. The unit operates on a standard 24V DC (± 10%) power supply with a highly efficient maximum power consumption of only 4W.
Mechanical Design & Protection
Designed for space-efficient installation, the 3BHT410082R0001 features a compact form factor with dimensions of 120 mm in width and 90 mm in height. It is strictly designed for DIN rail mounting, ensuring a secure fit within industrial control cabinets. With an IP20 protection class, the module is shielded against solid objects while operating effectively in temperatures ranging from -5°C to +60°C. This allows for reliable deployment in various factory floor conditions without compromising performance.
Technical Specifications
| Technical Parameter | Detailed Specification |
|---|---|
| Bus Type | Ethernet-based (10/100 Mbps) |
| Connection Interface | RJ45 (Cat 5e or higher) |
| Power Supply | 24V DC ± 10% (Max 4W) |
| Capacity | Up to 16 devices |
| Net Weight | 0.35 kg (0.77 lbs) |
| Operating Temp | -5°C to +60°C |
System Integration & Benefits
This extender is a critical component for Advant OCS users looking to modernize their bus communication. By moving to an Ethernet-based system, users gain the advantage of standard networking hardware and improved data throughput compared to legacy proprietary bus systems. Its plug-and-play compatibility with standard automation hardware reduces commissioning time and simplifies long-distance signal extension within large-scale industrial plants.
Engineering Advantages
- High Reliability: Designed for 24/7 continuous operation with robust error-checking protocols.
- Standardized Ports: Uses common RJ45 connectors, eliminating the need for expensive proprietary cables.
- Enhanced Diagnostics: Three distinct LED indicators provide immediate visual feedback on module performance.
- Low Heat Footprint: Efficient 4W power consumption ensures the module contributes minimally to the thermal load of the cabinet.
Technical FAQs
Q1: What type of network cable is recommended for this module?
A1: Category 5e (Cat 5e) or higher Ethernet cabling is required to achieve the full 10/100 Mbps data rate and ensure noise immunity.
Q2: Can I mount this module in any orientation?
A2: For optimal heat dissipation and secure fit, it is recommended to mount the module vertically on a standard 35mm DIN rail.
Q3: Is this module compatible with legacy Advant Bus?
A3: This specific model is Ethernet-based. Please verify your controller's interface requirements to ensure compatibility with Ethernet-based bus extension protocols.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...