Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:8440-1934
8440-1934 Woodward Genset Controller Breaker Display 12/24V
Manufacturer: Woodward
Product No.: 8440-1934
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 1850g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
8440-1934 Woodward easYgen-2500 Breaker Control Operator Interface
8440-1934 is a Woodward easYgen-2500 operator interface for breaker control. Features color LCD display, front panel mounting, 12/24 Vdc supply, 19W max consumption. Includes 32/32 discrete I/O and 16/4 analog I/O. Designed for genset control and protection applications.
Core Technical Advantages
- Breaker Control: Dedicated operator interface for generator breaker management and synchronization.
- Color LCD Display: Large graphical display with multilingual support for easy operation.
- Extensive I/O: 32 discrete inputs, 32 discrete outputs, 16 analog inputs, and 4 analog outputs.
- True RMS Sensing: Class 1 accuracy for voltage (120/480 VAC) and current (1A/5A) measurements.
- Versatile Power: 12/24 Vdc supply with wide 8-40 Vdc operating range, 19W max consumption.
- IP66 Front Sealing: Front panel IP66 rated for harsh environments. Plastic housing, 282×217×99 mm.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 8440-1934 |
| Description | easYgen-2500 Breaker Control Operator Interface |
| Supply Voltage | 12/24 Vdc (8 - 40 Vdc) |
| Power Consumption | 19 W Max |
| Display | Color LCD |
| Mounting | Front Panel |
| Discrete Inputs | 32 |
| Discrete Outputs | 32 |
| Analog Inputs | 16 (0-500Ω, 0-20mA) |
| Analog Outputs | 4 (±10V / ±20mA / PWM) |
| Voltage Sensing | 120/480 VAC true RMS, Class 1 |
| Current Sensing | 1A/5A true RMS, Class 1 |
| Housing | Plastic, Front Panel |
| Dimensions (W×H×D) | 282 × 217 × 99 mm |
| Sealing | IP66 (front) / IP20 (rear) |
| Weight | approx. 1,850 g |
| Operating Temp | -20 to 70°C |
| Brand | Woodward |
Installation & Maintenance Guide
- Mounting: Front panel installation. Cutout dimensions follow Woodward easYgen-3200 specification. Plastic housing, 282×217×99 mm.
- Power Supply: Connect 12/24 Vdc (8-40 Vdc range). Ensure capacity for 19W max consumption.
- Voltage Sensing: Connect 120 VAC or 480 VAC true RMS inputs. Class 1 accuracy.
- Current Sensing: Use 1A or 5A CTs. Isolated true RMS inputs with Class 1 accuracy.
- I/O Wiring: 32 discrete I/O (12/24 Vdc range), 16 analog inputs (0-500Ω / 0-20mA), 4 analog outputs (±10V / ±20mA / PWM).
- Communication: Supports CAN open, J1939, Modbus RTU, and modem.
- Environment: Operating temperature -20 to 70°C. IP66 front sealing for harsh conditions.
Engineering Advantages & Compatibility
Designed for Woodward easYgen-2500 genset control systems. Supports standalone emergency, isochronous parallel (up to 32 gensets), cogeneration, and utility paralleling applications. LogicsManager enables complex controls combining measured values, internal conditions, and I/O states. Remote panel RP-3000 compatible. Multilingual graphical display supports global deployment.
Technical FAQs
Q1: What is the difference between 8440-1934 and other easYgen models?
A1: 8440-1934 is the operator interface for easYgen-2500 breaker control. Plastic housing, front panel mount, 282×217×99 mm. Back panel version has sheet metal housing (250×228×84 mm).
Q2: How many gensets can be controlled?
A2: Supports isochronous parallel operation of up to 32 gensets in island mode or paralleled to utility.
Q3: What communication protocols are supported?
A3: Supports CAN open, J1939, Modbus RTU, and modem communication for SCADA and external I/O integration.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
What are real costs of fragmented brownfield control systems?
This article presents a production-focused data interconnection architecture that resolves multi-vendor control syste...
-
Can Compact PLCs Deliver Smart Benefits Without Shutdowns?
This technical article examines incremental smart retrofit strategies using Allen‑Bradley Compact control hardware fo...
-
Can Online Vibration Prevent Critical Rotating Asset Failures?
Online vibration acquisition has evolved from a basic trip-protection tool to a strategic financial safeguard for cri...
-
Is Centralized I/O Holding Back Your Smart Factory Upgrade?
This article explores how Allen‑Bradley distributed I/O enables modular production control, addressing the limitation...
-
Can ABB’s Signal Linkage Cut Downtime 60%?
This article examines how ABB’s multi-layer industrial communication architecture resolves cross-equipment signal mis...
-
Is Your Gas Detection Transmitter Costing You Millions?
Fixed calibration schedules waste millions and hide critical risks. This article presents a data-driven, risk-tiered ...
