Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:330905-00-10-05-02-05
330905-00-10-05-02-05 Bently Nevada 0.5m Non-Armored Proximity Probe
Manufacturer: Bently Nevada
Product No.: 330905-00-10-05-02-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 17g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The 330905-00-10-05-02-05 is a premium, unarmored 3300 NSv eddy current proximity probe manufactured by Bently Nevada for high-precision machinery diagnostics. Featuring an M10x1 threaded case design with a lightweight, standard unarmored mass profile of 34 g/m for its FEP coaxial cable, this 0.5-meter transducer accurately tracks axial displacement, radial vibration, and shaft speed. Engineered with advanced chemical resilience and superior side-view clearances, it is optimized for tight spaces inside industrial process compressors, pumps, and high-speed steam turbines where standard probes encounter side-wall interference.
Core Technical Advantages
-
Detailed Suffix Logic Breakdown:
- -00-: Selects 0 mm of unthreaded length on the main probe barrel.
- -10-: Specifies an extended 100 mm overall case length for deeper insertion depth.
- -05-: Configures a total physical and electrical cable length of 0.5 meters (20 inches).
- -02-: Integrates a miniature coaxial ClickLoc connector on a standard, non-armored FEP line.
- -05-: Provides multiple global hazardous area agency safety certifications and approvals.
- Enhanced Chemical Resistance: Features a high-grade Polyphenylene Sulfide (PPS) tip and an AISI 304 stainless steel case, offering significantly higher resistance to corrosive industrial gases than legacy 3300 RAM setups.
- Strict Calibration Accuracy: Delivers a calibrated Incremental Scale Factor (ISF) of 7.87 V/mm (200 mV/mil) over a 1.5 mm (60 mils) linear spectrum, backed by an internal terminal resistance of 4.0 $\pm$ 0.5 $\Omega$.
- Narrow-Field Side Clearance: Engineered with a focused eddy current field that outperforms legacy 3000-series 190 probes, allowing the tip to sit near counterbores or recessed walls without experiencing signal distortion.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Number | 330905-00-10-05-02-05 |
| Product Line | 3300 NSv Series (Narrow System variant) |
| Thread & Case Profile | M10X1 thread; 0mm unthreaded length; 100mm overall case length |
| Component Weight Profile | Standard Unarmored Cable: 34 g/m (0.4 oz/ft) | Total Net Cable Mass: 0.017 kg |
| Linear Measuring Range | 1.5 mm (60 mils), spanning from 0.25 mm to 1.75 mm (-1 to -13 Vdc) |
| Probe DC Resistance ($R_{PROBE}$) | 4.0 $\pm$ 0.5 $\Omega$ (Center Conductor to Outer Conductor) |
| Frequency Response | 0 to 10 kHz (+0, -3 dB typical with up to 305m of field wiring) |
| Thermal Limitations | -52°C to +177°C (-62°F to +351°F) operating/storage temperature |
| Pressure Rating Barrier | Differential pressure seal between tip and case via Viton O-ring |
| Agency Approvals | Option 05 (Multiple global hazardous area certifications) |
Installation & Maintenance Guide
Case Mounting and Torque Limits
When screwing the 100mm case into mounting brackets, ensure the maximum thread engagement length does not exceed 15 mm. For the first three active threads, the absolute maximum rated torque is 22.6 N·m (200 in·lb). To prevent case distortion and maintain threads, engineers recommend tightening to a nominal torque of 7.5 N·m (66 in·lb).
Connector and Bend Radius Management
The miniature coaxial ClickLoc connector clicks firmly into place with a secure latch. Connectors should be mated finger-tight, with a maximum torque limit of 0.56 N·m (5 in·lb). Route the unarmored FEP cable smoothly, ensuring a strict minimum bend radius of 25.4 mm (1.0 inch) to safeguard internal conductor layers.
Target Diameter and Gapping Requirements
For optimum accuracy against standard AISI 4140 steel targets, the flat target surface requires a recommended minimum diameter of 13 mm (0.5 in). If tracking shafts smaller than 13mm, scale factor changes will occur. Reduce the gap setting below the default 1.0 mm (40 mils) recommendation to minimize these errors.
Engineering Advantages
- Drop-In Retrofitting: Fully mechanically and electrically interchangeable with legacy Bently Nevada 3300 RAM proximity probes, enabling asset monitoring system upgrades without rewiring entire cabinets.
- Reduced Mechanical Load: At an ultralight 34 g/m for the unarmored line, this 0.5m probe configuration introduces minimal mechanical strain, preventing terminal connector fatigue inside internal junction boxes.
- High Humidity Stability: Exhibits exceptional environmental protection, sustaining less than a 3% change in Average Scale Factor (ASF) when subjected to 93% relative humidity for up to 56 days under IEC 68-2-3 standards.
Technical FAQs
Q1: Why is this 3300 NSv probe body configured with 0mm unthreaded length (-00-)?
A1: The 0mm unthreaded length option means the entire 100mm case length is fully threaded. This allows maximum adjustment flexibility through bracket sleeves, making it ideal for deep-recessed port designs.
Q2: Can this 0.5-meter probe connect directly to a monitor rack without an extension cable?
A2: No. Eddy current proximity systems are calibrated for precise total electrical lengths (typically 5.0m or 9.0m). This 0.5m probe must be matched with a corresponding 3300 NSv extension cable to achieve the required overall system length.
Q3: Is the internal Viton O-ring pressure tested at the factory prior to shipping?
A3: No, standard builds are designed and rated to seal pressure differentials, but they are not pressure tested before leaving the factory. If your process compressor mandates certified seals, contact our application team for a custom test option.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Bilelikdäki dolandyryşy optimizasiýa etmek önümçilikde OEE-ni 20% ýokarlandyryp biler mi?
Adaty biri-birinden üzňe PLC we DCS ulgamlary önümçilik tapgyrlarynyň arasynda günde 10–18% boş durluşa sebäp bolýar....
-
Hierarhiýaly dolandyryş zawodynyň OEE-sini 64 %-den 82 %-e nähili ýokarlandyrýar?
Bu makalada hierarhiki bulut-çet hyzmatdaşlyk dolandyryşynyň böleklenen senagat arhitekturalarynyň ornuny nädip tutýa...
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...