Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1794-OB16
1794-OB16 Allen-Bradley Flex I/O 16 Sourcing Output
Manufacturer: Allen-Bradley
Product No.: 1794-OB16
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 78g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley 1794-OB16 Flex I/O DC Sourcing Output Module
Allen-Bradley 1794-OB16 | Flex I/O discrete DC output module with 16 sourcing output channels. Operates at 24V DC nominal voltage with 8.0 A total output current rating. Compatible with 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, and 1794-TB3SK terminal bases. Weight: approximately 78 g (2.75 oz).
Key Features
16 sourcing output channels. 24V DC nominal on-state voltage (10-31.2V DC range). 8.0 A total output current rating (500 mA per channel). Maximum on-state voltage drop 0.5V DC. Maximum off-state leakage 0.5 mA. 50V continuous isolation voltage. Surge current 2 A for 50 ms, repeatable every 2 seconds. Output signal delay 0.5 ms (OFF-to-ON) and 1 ms (ON-to-OFF). 80 mA Flexbus current at 5V DC. 16 yellow status indicators. Keyswitch position 2. Supports up to 8 modules per Flex I/O rack.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OB16 |
| Product Type | Flex I/O Digital DC Output Module |
| Outputs | 16 (Sourcing) |
| On-State Voltage (Nominal) | 24V DC |
| On-State Voltage (Min) | 10V DC |
| On-State Voltage (Max) | 31.2V DC |
| Output Current Rating | 8.0 A (total) |
| On-State Current (Min) | 1 mA per channel |
| On-State Current (Max) | 500 mA per channel |
| On-State Voltage Drop | 0.5V DC max |
| Off-State Leakage Current | 0.5 mA max |
| Isolation Voltage | 50V continuous |
| Surge Current | 2 A for 50 ms, repeatable every 2 s |
| Signal Delay (OFF-to-ON) | 0.5 ms |
| Signal Delay (ON-to-OFF) | 1 ms |
| Flexbus Current | 80 mA @ 5V DC |
| Power Dissipation | 5.3 W @ 31.2V DC max |
| Thermal Dissipation | 18.1 BTU/hr @ 31.2V DC max |
| Indicators | 16 Yellow status indicators |
| Keyswitch Position | 2 |
| Enclosure | Open-type |
| Mounting | DIN Rail |
| Dimensions (H x W x D) | 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) |
| Weight | Approx. 78 g (2.75 oz) |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Vibration | 5g @ 10-500 Hz |
| Operating Shock | 30 g |
| Certifications | c-UL-us, CSA, CE, Ex, TÜV, KC, EAC, RCM |
| UPC | 10612598137852 |
Installation Notes
Install on compatible terminal base with keyswitch set to Position 2. Compatible terminal bases: 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK. This module has no internal fusing; install external fusing as required by the system (recommended: SAN-O MQ4-800 mA). Supports up to 8 modules per Flex I/O rack. Can also be used as local I/O adapter for FlexLogix Controller or 1794-FLA extender. Wire size determined by installed terminal base.
Engineering Advantages
16 sourcing outputs in a single Flex I/O module maximize channel density. High 8.0 A module rating handles demanding DC loads directly. Fast 0.5 ms OFF-to-ON response supports time-critical control applications. 16 yellow status indicators simplify field diagnostics. Supports distributed I/O architecture via any 1794 Flex I/O adapter. Wide certification portfolio (c-UL-us, CSA, CE, Ex, TÜV, KC, EAC, RCM) enables global deployment.
FAQs
Q1: How many outputs does this module provide?
A1: 16 sourcing DC outputs, 500 mA per channel.
Q2: What is the output voltage range?
A2: 10-31.2V DC, with a nominal rating of 24V DC.
Q3: Does this module include internal fusing?
A3: No internal fusing. External fusing is recommended (SAN-O MQ4-800 mA) as required by the system.
Goşmaça spesifikasiýalar
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...