Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1746-NR4
1746-NR4 Allen-Bradley Resistance Temperature Detector Module
Manufacturer: Allen-Bradley
Product No.: 1746-NR4
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 540g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1746-NR4 is a high-precision RTD (Resistance Temperature Detector) input module designed for the SLC 500™ controller platform. This module provides four backplane-isolated channels capable of interfacing with a variety of RTD sensors to provide accurate temperature data for industrial processes. With built-in linearization and self-calibration features, the 1746-NR4 ensures high-fidelity signal conversion and long-term stability in demanding thermal monitoring applications.
Technical Configuration
- Manufacturer: Allen-Bradley / Rockwell Automation
- Product Line: SLC 500 I/O
- Catalog Number: 1746-NR4
- Number of Channels: 4 (Backplane Isolated)
- Backplane Current Draw: 50 mA at 5V DC; 50 mA at 24V DC
- Isolation Voltage: 500 Volts for 1 minute
- Terminal Wire Size: Up to two 2.5 mm² (14 AWG) per terminal
Technical Specifications
| Net Weight | 0.54 kg (1.19 lbs) | Operating Temp | 0 to 60 °C (32 to 140 °F) |
| Power Consumption | 1.5 W Max | Humidity | 5% to 95% (Non-condensing) |
| Certifications | CE, UL Listed, C-Tick Certified | ||
Installation & Wiring Features
1. Signal Isolation: The 1746-NR4 features 500V operating isolation between the RTD inputs and the backplane. This protects the SLC 500 CPU from electrical noise and potential transients originating from field sensors, ensuring system-wide reliability in electrically noisy environments.
2. Wiring Capacity: The module supports a maximum termination wire size of two 2.5 mm² (14 AWG) wires per terminal. This allows for robust physical connections and facilitates "daisy-chaining" of common leads where required by specific RTD configurations (2-wire, 3-wire, or 4-wire).
3. Thermal Management: Designed to operate efficiently within a range of 0 to 60 °C, the module consumes a maximum of 1.5W of power. Its low heat dissipation footprint allows it to be installed in high-density SLC 500 racks without requiring specialized cooling, provided standard enclosure ventilation is maintained.
Engineering Advantages
The Allen-Bradley 1746-NR4 is engineered for precision. By converting analog resistance signals directly into digital values for the SLC 500 backplane, it eliminates the need for external signal conditioners. The module's compatibility with standard certifications (CE, UL, C-Tick) ensures it meets global safety and electromagnetic compatibility standards, making it a dependable choice for international machinery manufacturers and process plants.
Technical FAQs
Q1: What types of RTDs does the 1746-NR4 support?
A1: The module is designed to work with standard Platinum, Nickel, and Copper RTDs. Please refer to the user manual for specific resistance curves and configuration settings.
Q2: Is an external power supply required?
A2: No, the 1746-NR4 draws its required operating power (50 mA at 5V and 24V DC) directly from the SLC 500 chassis backplane.
Q3: Can channels be configured independently?
A3: Yes, each of the four channels is isolated and can be configured through the controller software to match the specific RTD type connected to that port.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...