Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:2094-BC02-M02-S
15kW IAM 2094-BC02-M02-S Allen-Bradley Kinetix 6000
Manufacturer: Allen-Bradley
Product No.: 2094-BC02-M02-S
Product Type: Axis Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 5080g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley Kinetix 6000 Integrated Axis Module 2094-BC02-M02-S
The 2094-BC02-M02-S is a 400V class Integrated Axis Module (IAM) from the Allen-Bradley Kinetix 6000 Drive system. This module operates on 324-528V AC 3-phase input (360-480V nominal) with 47-63 Hz frequency. It delivers 15 kW continuous output power to bus and 22.6A continuous output current. Featuring Safe Torque-Off (STO) functionality and 97% efficiency, this IAM has a remarkable 200,000 A (rms) symmetrical short-circuit current rating.
Core Specifications
- Manufacturer: Rockwell Automation
- Brand: Allen-Bradley
- Series: Kinetix 6000
- Model: 2094-BC02-M02-S
- Product Type: Integrated Axis Module (IAM) - 400V Class
- Module Type: IAM 400 Volt Class
- Efficiency: 97%
- Short-Circuit Current Rating: 200,000 A (rms) symmetrical
AC Input Specifications
- AC Input Voltage: 324-528V rms 3-Phase (360-480V nominal)
- AC Input Frequency: 47-63 Hz
- AC Input Current (nominal rms): 24.0 A
- AC Input Current (max inrush 0-pk): 22.0 A
DC Input Specifications (Common Bus Follower)
- DC Input Voltage: 458-747 VDC
- DC Input Current: 22.6 A
Control Power Specifications
- Control Power AC Input: 95-264V AC rms, 1-phase
- Control Power Nominal: 110-240V AC rms
Output Specifications
- Continuous Output Power to Bus: 15 kW
- Continuous Output Current to Bus: 22.6 A
- Peak Power Output (Series A): 30 kW
- Peak Power Output (Series B, C, D): 37.5 kW
Bus Protection Specifications
- Bus Overvoltage: 825 VDC
- Bus Undervoltage: 275 VDC
- Nominal Bus Output Voltage: 650 VDC
Internal Shunt Specifications
- Internal Shunt Continuous Power: 50 W
- Internal Shunt Peak Power: 5.6 kW
- Internal Shunt Resistor: 115 Ohms
- Shunt On Voltage: 805 VDC
- Shunt Off Voltage: 755 VDC
Internal Components
- Converter Inductance: 500 µH
- Converter Capacitance: 110 µF
Power Dissipation by Loading
- 20% Loading: 36 W
- 40% Loading: 44 W
- 60% Loading: 54 W
- 80% Loading: 64 W
- 100% Loading: 75 W
Peak Current Ratings
- Standard Peak Inverter Current Rating: 150%
- Peak Enhanced Inverter Current Rating: 250%
- Peak Converter Current (Series A): 200%
- Peak Converter Current (Series B, C): 250%
Physical Specifications
- Weight: 11.2 lbs (5.08 kg)
Compatible Components
- Axis Module: 2094-BM02-S
Recommended Protection Devices
- Bussmann Fuses: FNQ-R-10 (10 Amps) or FNQ-R-7.5 (7.5 Amps)
- Allen-Bradley Circuit Breakers: 1492-SPM2D060 or 1492-SPM1D150 (not UL-listed)
Key Features
- 97% efficiency for optimal energy performance
- 15 kW continuous output power to bus
- 22.6A continuous output current
- Safe Torque-Off for enhanced operator safety
- Exceptional 200,000 A short-circuit rating
- Common bus follower capability with DC input
- Peak power output up to 37.5 kW for Series B/C/D
- Compatible with 2094-BM02-S Axis module
Technical Documentation
📥 Download Product Datasheet PDF
FAQ
Q1: What is the power rating of the 2094-BC02-M02-S Integrated Axis Module?
It delivers 15 kW continuous output power to bus with 22.6A continuous output current, weighing 5.08 kg (11.2 lbs).
Q2: What are the peak power ratings for different series?
Series A provides 30 kW peak power, while Series B, C, and D deliver 37.5 kW peak power with 250% peak enhanced current rating.
Q3: What safety and protection features does this module include?
It includes Safe Torque-Off (STO), bus overvoltage (825V DC) and undervoltage (275V DC) protection, plus an exceptional 200,000 A short-circuit current rating.
Goşmaça spesifikasiýalar
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Why Is 99.8% Reliability Critical for Your PLC and DCS Systems?
This article explains why rigorously vetted cross-border control parts stabilize industrial automation operations. It...
-
Bilelikdäki dolandyryşy optimizasiýa etmek önümçilikde OEE-ni 20% ýokarlandyryp biler mi?
Adaty biri-birinden üzňe PLC we DCS ulgamlary önümçilik tapgyrlarynyň arasynda günde 10–18% boş durluşa sebäp bolýar....
-
Hierarhiýaly dolandyryş zawodynyň OEE-sini 64 %-den 82 %-e nähili ýokarlandyrýar?
Bu makalada hierarhiki bulut-çet hyzmatdaşlyk dolandyryşynyň böleklenen senagat arhitekturalarynyň ornuny nädip tutýa...
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...