Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:VFD004EL21W-1
0.5HP 230V Delta VFD004EL21W-1 Sensorless Vector Drive
Manufacturer: Delta
Product No.: VFD004EL21W-1
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Description
Product Overview
The VFD004EL21W-1 is a highly advanced, ultra-compact micro AC drive from Delta’s streamlined EL-W series. Rated for 0.5 HP (0.4 kW), this versatile drive brings sophisticated motor control to low-horsepower applications by supporting both standard V/F scalar and Sensorless Vector Control (SVC) modes. Operating from a 1-phase 230 V AC supply, it provides a stable 2.5 A output current. With integrated multi-pump orchestration, a built-in PID feedback controller, and a high overload threshold of 150% for up to 60 seconds, this lightweight, small-footprint drive delivers premium performance for precise fan, pump, and conveyor automation layout designs.
Core Technical Advantages
Sensorless Vector Control (SVC) Integration
Unlike standard micro drives that only offer scalar control, this model integrates advanced Sensorless Vector Control. SVC reads motor back-EMF variations dynamically to deliver stable, high-torque output even at low operating speeds, providing superior velocity regulation without the cost of encoder feedback hardware.
Intelligent Multi-Pump and PID Automation
The integrated PID feedback loop monitors process variables like pressure or flow rate in real time. Combined with specialized single/multi-pump firmware algorithms, the drive adjusts motor speed automatically to maintain constant line pressures, cutting system energy waste and reducing mechanical wear.
Robust Heavy-Duty Overload Capacity
Engineered to manage challenging high-friction startups, the internal power modules support an overload threshold of 150% for up to 60 seconds. This capability prevents nuisance tripping when accelerating demanding or high-inertia industrial loads.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Products (VFD EL-W Series) |
| Model Number | VFD004EL21W-1 |
| Motor Power Rating | 0.5 HP / 0.4 kW |
| Rated Output Amps | 2.5 Amps |
| Input Sourcing Voltage | 1-Phase, 230 V AC |
| Output Frequency Range | 0.1 to 400.00 Hz |
| Control Modes Available | V/F (Scalar), SVC (Sensorless Vector Control) |
| Serial Communication | MODBUS COM Port (Built-in) |
| Overload Capacity | 150% of Rated Current for 60 Seconds |
| Approximate Net Weight | 1.0 kg (2.2 lbs) |
Installation and Maintenance
Panel Mounting Clearance
Install the drive vertically on standard DIN rails inside an IP20 or higher enclosure panel. Because the model relies on a compact, lightweight chassis with an efficient internal heatsink design, keep a minimum of 50 mm clearance above and below the drive to ensure cooling air shifts unimpeded across the back surface.
Power and Serial Layouts
Wire incoming 1-phase AC lines directly to terminals L1 and L2. Route the motor cable connection directly to terminals U, V, and W. For SCADA or PLC networking, use the built-in RJ45 MODBUS communication terminal block. Keep serial RS-485 signal cables separate from high-power line cables to minimize electromagnetic noise pickup.
Deceleration Stall Safeguards
This drive does not include an integrated dynamic braking chopper ($Braking\ Chopper:\ NA$). For high-inertia loads or operations requiring swift speed deceleration, activate the intelligent overvoltage and overcurrent stall prevention parameters in the firmware. This tells the drive to control deceleration slopes automatically to prevent DC bus trips.
Engineering Advantages
Integrated Digital Keypad
The non-detachable built-in keypad features sharp digital parameter displays and intuitive layout buttons. Maintenance technicians can query active fault profiles, track live load current, or configure pump PID targets instantly on the factory floor without connecting an external PC interface.
Advanced Stalling Prevention
Smart firmware actively tracks current and bus voltage fluctuations. If an overvoltage or overcurrent condition starts to develop during quick ramps or load changes, the stall prevention logic slows adjustments automatically until electrical balances clear.
Reduced Components Cost
By providing built-in MODBUS communications, full PID control functionality, and high-performance Sensorless Vector algorithms, this inverter removes the need for standalone system components, reducing total panel production costs.
Technical FAQs
Q1: How do I choose between V/F control mode and Sensorless Vector Control (SVC) for my machine?
A1: Use V/F mode for basic applications like centrifugal exhaust fans or centrifugal water pumps where load torque drops at lower speeds. Select SVC mode for machines like mixers, indexing conveyors, or positive displacement pumps that require steady, high torque and tight speed regulation at low operating frequencies.
Q2: Can this model be wired to specialized Ethernet protocols like Modbus TCP or EtherNet/IP?
A2: No. This compact EL-W variant is designed with a native MODBUS serial port to keep production costs low. It does not natively support advanced industrial Ethernet protocols like Modbus TCP, EtherNet/IP, PROFINET, or EtherCAT.
Q3: How does the built-in PID loop optimize multi-pump applications?
A3: The drive processes an incoming analog sensor signal (e.g., from a 4-20 mA fluid pressure transducer) and contrasts it with a programmed setpoint. It adjusts output speed continuously to preserve that target, and can switch or cycle auxiliary pump starters via digital outputs during demand peaks.
Goşmaça spesifikasiýalar
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...