Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:8440-2049
Woodward easYgen-3200 8440-2049 Control Module HMI
Manufacturer: Woodward
Product No.: 8440-2049
Product Type: Control Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1800g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Woodward 8440-2049 is a sophisticated genset management controller belonging to the easYgen-3000 / easYgen-3200 series platform. Engineered for complex power generation system management, this controller coordinates automatic load sharing, synchronizing, and breaker control for up to 32 interconnected engine-generator sets operating in island or mains-parallel modes.
Operating on a nominal 12/24 V DC power supply, the 8440-2049 incorporates an integrated front-panel Human Machine Interface (HMI) equipped with soft keys and a 5.7-inch monochrome LCD. Housed in a 282 x 216 x 96 mm enclosure, the unit weighs 1.80 kg (3.97 lbs) with an estimated gross package shipping weight of 2.50 kg (5.51 lbs), supporting multi-language menu navigation across 14 global languages.
Core Technical Advantages
- Multi-Genset Load Management: Manages complex load-sharing configurations and breaker synchronization for up to 32 generator units via CAN bus network.
- Comprehensive Breaker Control: Provides open/closed transition, soft loading/unloading, slip frequency matching, and phase angle synchronization for generator and utility breakers.
- Intuitive Multi-Lingual Display: Features a 5.7-inch LCD screen with multi-level password protection and support for 14 operational languages (including English, Chinese, German, Spanish, and Russian).
- Versatile Network Integration: Fully compatible with major industrial automation architectures using serial RS-232, RS-485, and CAN communication interfaces.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Woodward |
| Part Number / Model | 8440-2049 |
| Product Series | easYgen 3000 / easYgen 3200 Series |
| Product Type | Engine-Generator Control & Synchronization Unit |
| Operating Power Supply | 12 / 24 V DC (8 to 32 V DC operating range) |
| Power Consumption | < 0.15 W max power consumption per path |
| Display / Operator Interface | 5.7" Graphical LCD with soft keys and status LEDs |
| Measurable Alternator Windings | 3p-3w, 3p-p-4w, 3p-4wOD, 1p-2w, 1p-3w |
| Current Transformer Setting Range | 1 A to 32,000 A adjustable |
| Output Relays | Galvanically Isolated Relay Contacts |
| Communication Interfaces | RS-232, RS-485, CAN Bus (Multi-protocol support) |
| Physical Front Dimensions | 282 mm (W) x 216 mm (H) x 96 mm (D) |
| Operating / Storage Temperature | Operation: -20 °C to +70 °C | Storage: -30 °C to +80 °C |
| Estimated Net / Shipping Weight | Net Unit: 1.80 kg (3.97 lbs) | Gross Shipping: 2.50 kg (5.51 lbs) |
Installation & Commissioning Setup
- Cutout & Panel Mounting: Mount flush in switchgear door panel using supplied clamp fasteners, adhering to standard 282 x 216 mm cutout dimensions.
- Control Power Connection: Connect filtered 12 V or 24 V DC system supply with reverse-polarity protection to the primary power input terminals.
- Communication Bus Wiring: Wire CAN bus connections using shielded twisted-pair cable with 120 Ω terminal resistors at both ends of the load-sharing network.
Technical FAQs
Q1: How many generator sets can the Woodward 8440-2049 control in a single network?
A1: It can interface and control load sharing for up to 32 interconnected generator sets.
Q2: What CT secondary ratio setting range is supported?
A2: The primary current transformer setting range is adjustable from 1 A up to 32,000 A.
Q3: What alternator winding configurations can this controller measure?
A3: It supports 3p-3w, 3p-p-4w, 3p-4wOD, 1p-2w, and 1p-3w alternator winding systems.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
