Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:330877-080-36-05
Bently Nevada 330877-080-36-05 8m Triaxial Cable
Manufacturer: Bently Nevada
Product No.: 330877-080-36-05
Product Type: Extension Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 610g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The 330877-080-36-05 is a premium, high-integrity 3300 XL 50 mm Proximity Extension Cable manufactured by Bently Nevada (a Baker Hughes business). This highly specialized component is engineered for demanding machinery protection systems, where it continuously transmits raw eddy-current signals from a 50 mm proximity probe to a remote Proximitor sensor. Unlike standard consumer components, this industrial cable features option **05 (Multiple Approvals)**, making it fully certified for installation within hazardous, explosive, and intrinsically safe areas globally. Comprising an 8.0-meter unarmored FluidLoc triaxial line, it offers long-distance routing flexibility on critical asset skids such as gas turbines, large compressors, and heavy hydro-turbines. Maintained in original factory packing with a full 12-month factory warranty, this brand-new unit has a net hardware weight of approximately 1.35 lbs (approx. 0.61 kg).
The visual highlights the unarmored, lightweight design of the core FluidLoc configuration. Its distinct light-blue outer jacket is highly visible inside industrial wiring conduits, while the integrated protective caps shield the precision miniature coaxial interfaces from field debris and contamination prior to final loop installation.
Core Technical Advantages
- Global Hazardous Area Certifications (Option 05): Specifically designed and validated to meet strict international standards (including ATEX, IECEx, and North American CSA/FM rules). This ensures the cable can safely operate in Class I, Division 1/Zone 0 environments when connected via an approved intrinsic safety barrier.
- FluidLoc Ingress Prevention: Features an engineered internal wicking barrier along the triaxial core. If the outer jacket suffers a cross-sectional cut in the field, this barrier stops lubricating oil, moisture, or process gases from migrating inside the cable sheath into clean instrument enclosures.
- Advanced Noise-Rejecting Architecture: Formed with a 75 Ω triaxial layout insulated with top-tier Perfluoroalkoxyethylene (PFA). This premium multi-shielded design provides extreme immunity to electromagnetic interference (EMI) and radio frequency interference (RFI) generated by nearby heavy-duty machinery.
- Broad Temperature Resilience: Designed to maintain constant electrical properties across an extreme operating spectrum of -51°C to +200°C (-31°F to +392°F), resisting degradation from bitter sub-zero exposures or intense radiant machinery heat.
Technical Specifications
| Parameter Attribute | Factory Specification Data |
|---|---|
| Brand / Manufacturer | Bently Nevada / Baker Hughes |
| Part / Catalog Number | 330877-080-36-05 |
| Product Model Family | 3300 XL 50 mm Proximity Series |
| [080] Cable Length Option | 8.0 Meters (Equivalent to 26.2 Feet) |
| [36] Armor & Cable Option | FluidLoc Triaxial Cable (Unarmored Structure) |
| [05] Agency Approvals | Multiple Approvals (ATEX, IECEx, CSA, FM Certified) |
| Center-to-Coaxial Resistance | 2.0 ± 0.5 Ω (DC Core Conductor Measurement) |
| Coaxial-to-Coaxial Resistance | 0.6 ± 0.2 Ω (Outer Shield Return Path) |
| Cable Material Insulation | 75 Ω Triaxial Perfluoroalkoxyethylene (PFA) |
| Net Weight Profile | Approx. 1.35 lbs (0.61 kg) (Net hardware line mass) |
| Condition / Warranty | New & Original in Sealed Box | 12-Month Factory Warranty |
| Temperature Rating Envelope | -51°C to +200°C (-31°F to +392°F) for both Operation and Storage |
Model Number Breakdown
The catalog structure for 330877-080-36-05 translates directly to the following hardware matrix criteria:
- 330877: Base model designation for the heavy-duty 3300 XL 50 mm Extension Cable lineup.
- 080: Designates a physical cable extension length of exactly 8.0 meters (26.2 feet).
- 36: Specifies the proprietary, unarmored FluidLoc triaxial design, maximizing chemical resistance while maintaining a flexible physical footprint.
- 05: Implements the **Multiple Approvals** option block, providing full hazardous zone explosion protection compliance (Intrinsically Safe and Non-Incendive ratings).
Field Installation & Loop Calibration Guidelines
- Total Matched Tuning Rule: To maintain strict system calibration linearity, the cumulative electrical length of the extension cable plus the proximity probe must perfectly match the total system length configured on your Proximitor Sensor. Because this extension cable is precisely 8.0 meters long, it must be paired with a 1.0-meter proximity probe to achieve a standard 9.0-meter loop setup. Running a mismatched combination will alter the circuit's base impedance, rendering your vibration and thrust displacement measurements highly inaccurate.
- Hazardous Location Verification: Because this model is configured with the option 05 approval block, ensure that all installation parameters align perfectly with the factory-supplied intrinsic safety control drawings. Maintain clean, segregated routing away from non-intrinsically safe cabling inside junction boxes, and verify that ground-loop isolation is verified before powering the monitoring system.
- Connector Protection & Handling: When connecting the high-precision miniature coaxial interfaces, prevent twisting or scraping the central conductor pin. To prevent loosening caused by heavy machinery vibration, ensure the connectors are fully seated. Bently Nevada strongly recommends wrapping the mated connection in self-fusing silicone tape or housing it in an external connector protector sleeve to shield the unarmored connection point from oil mist ingress.
Technical FAQs
Q1: What separates the option "05" approval code from the standard option "00" cable?
A1: Physically, the cables look and perform identically under normal conditions. However, the option 05 variant undergoes strict quality control and regulatory certification audits to verify its safe electrical profile in explosive environments. Option 00 lacks these certificates and cannot be used legally in hazardous plant areas that mandate explosion-proof or intrinsically safe equipment.
Q2: Why are the DC resistance values higher on this model than on shorter cables?
A2: Electrical resistance is directly proportional to line length. This 8.0-meter assembly exhibits a center conductor resistance of 2.0 ± 0.5 Ω, which is exactly double that of a 4.0-meter cable (1.0 ± 0.25 Ω). Field technicians performing loop diagnostic checks must cross-reference these values to prevent false failure conclusions.
Q3: Does the unarmored FluidLoc jacket offer enough physical defense without a steel conduit?
A3: The PFA jacket provides superb defense against chemical splash, cutting, and tearing. However, since it is an unarmored cable weighing just 1.35 lbs, it should always be routed through dedicated conduit pipes or cable trays if it passes through open areas exposed to flying metal debris, heavy tool drops, or maintenance foot traffic.
Additional Specifications
- Silver
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can PLC Rewriting Replace Full Hardware Retrofit?
This article explains how cross-brand PLC code migration replaces full hardware replacement for legacy production lin...
-
Can Emerson Fix ISO 50001 Data Gaps in Old Factories?
This article explains why conventional PLC and DCS systems lack granular energy monitoring for ISO 50001 compliance. ...
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...
-
Is Your SME Process Factory Overpaying for Industrial Automation?
This article provides a data-driven guide for SME process factories to deploy right-sized DCS solutions without overs...
-
Why Did a $420,000 Shutdown Happen Despite CPU Redundancy?
This article presents 15 years of field-tested evidence showing how hidden single points of failure cause unplanned s...
