Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:HIEE300831R0001
UAC346AE01 ABB Terminal Unit | 24-240V AC/DC
Manufacturer: ABB
Product No.: HIEE300831R0001
Product Type: Terminal Unit
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1200g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
ABB HIEE300831R0001 UAC346AE01 Terminal Unit
The unit functions as a high-reliability industrial terminal block assembly designed for control systems and excitation platforms. It provides secure field wiring consolidation, distribution, and robust signal interface protection across wide operating voltage ranges.
Technical Specifications
| Manufacturer | ABB |
| Model / Catalog No. | HIEE300831R0001 / UAC346AE01 |
| Product Type | Terminal Unit |
| Voltage Range | 24 to 240 V AC/DC |
| Current Rating | 10 A maximum |
| Operating Temperature | -20°C to +60°C |
| Dimensions | 21.6 cm x 7.6 cm x 25.4 cm (8.5" x 3.0" x 10.0") |
| Net Weight | 1.2 kg (2.65 lbs) |
Quick Installation Guide
- Isolate all power lines completely before mounting or connecting field wires to prevent electrical shock.
- Ensure all wiring terminations match the specified 10 A max current capacity to avoid overheating.
- Verify physical alignment and torque terminal screws correctly to maintain secure connection integrity under high vibration.
Technical FAQs
Q1: Can this unit accept both AC and DC voltages simultaneously?
A1: No. While the hardware safely accommodates voltages within the 24-240 V range for either AC or DC supply configurations, individual circuits must isolate different power sources.
Q2: What is the maximum allowable load for this terminal unit?
A2: The module limits continuous current throughput to a maximum of 10 A. Exceeding this value risks thermal degradation.
Q3: Is this unit suitable for unventilated enclosures up to 60°C?
A3: Yes, the unit operates reliably up to +60°C, but you must ensure surrounding equipment spacing maintains adequate ambient airflow.
Additional Specifications
- Geometric
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...