Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TSXFPC10
TSXFPC10 Schneider Electric Interface Board FIPWAY FIPIO
Manufacturer: Schneider
Product No.: TSXFPC10
Product Type: Interface Board
Product Origin: FR
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric TSXFPC10 FIPWAY FIPIO Interface Board
Product Overview
Schneider Electric TSXFPC10 is a specialized interface board for FIPWAY and FIPIO connectivity. It operates within an ISA bus framework with configurable I/O addresses, IRQ levels, and DMA channels. Network address range 0 to 127 and station address range 0 to 63. CE, UL, and CSA certified.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | TSXFPC10 |
| Type | FIPWAY/FIPIO Interface Board |
| Product Line | TSX Micro PLCs |
| Bus Type | ISA (Industry Standard Architecture) |
| Network Address Range | 0 to 127 |
| Station Address Range | 0 to 63 |
| I/O Address Range | Configurable |
| IRQ Level | Configurable |
| DMA Channel | Configurable |
| Communication Protocols | FIPWAY, FIPIO |
| Power Supply | 5V DC from ISA bus |
| Dimensions | 80.96 x 106.68 x 12.7 mm |
| Operating Temperature | 0°C to +60°C |
| Humidity | 10% to 90% non condensing |
| LED Indicators | Status LEDs for communication and power |
| Certifications | CE, UL, CSA |
| Weight | 0.45 kg |
Installation
Install board in ISA bus slot. Configure I/O address range, IRQ level, and DMA channel per application. Connect FIPWAY or FIPIO network cable. Verify 5V DC power from ISA bus. Status LEDs indicate communication and power conditions. Operating temperature 0°C to +60°C.
Features
FIPWAY and FIPIO protocol support. ISA bus architecture for system integration. Configurable I/O addresses, IRQ levels, and DMA channels. Network address range 0 to 127. Station address range 0 to 63. Status LEDs for communication and power. CE, UL, and CSA certified.
FAQ
Q1: What bus type does this board use?
A1: ISA (Industry Standard Architecture) bus. Power supplied at 5V DC from the ISA bus slot.
Q2: What communication protocols are supported?
A2: FIPWAY and FIPIO protocols. Network address range 0 to 127 and station address range 0 to 63.
Q3: What are the configuration options?
A3: Configurable I/O address range, IRQ level, and DMA channel. Adapts to various operational requirements.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can You Restore a DCS Controller Without Downtime?
This article explains field-proven backup and recovery workflows for ABB AC800M DCS controllers. It covers pre-backup...
-
What Makes Live Honeywell Transmitter Replacement Safe?
This article explains how industrial automation teams can replace aging Honeywell transmitters online without a full ...
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
