Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TSXAEY1600
TSXAEY1600 Schneider Analog Input Module 16 Channel 12-Bit
Manufacturer: Schneider
Product No.: TSXAEY1600
Product Type: Analog Input Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric TSXAEY1600 Analog Input Module
Product Overview
The Schneider Electric TSXAEY1600 is a high-level analog input module for the TSX Micro and Modicon Premium PLC platforms. It features 16 analog input channels with 12-bit A/D conversion, supporting current (0-20 mA, 4-20 mA) and voltage (±10 V, 0-10 V, 0-5 V, 1-5 V) input types. The module provides 1000 Vrms isolation between channels and bus/ground. Weight is 0.34 kg (0.75 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | TSXAEY1600 |
| Product Line | TSX Micro / Modicon Premium |
| Product Type | Analog Input Module |
| Input Channels | 16 High-Level Analog Inputs |
| Input Types (Current) | 0-20 mA, 4-20 mA |
| Input Types (Voltage) | ±10 V, 0-10 V, 0-5 V, 1-5 V |
| A/D Conversion | 12 bits |
| Nominal Read Cycle Time | 51 ms |
| Fast Read Cycle Time | 3 ms + 3 ms per channel used |
| Measurement Error (25 °C) | 0.1% of full scale (voltage), 0.16% (current) |
| Measurement Error (0-60 °C) | 0.13% of full scale (voltage), 0.32% (current) |
| Isolation (Channels to Bus) | 1000 Vrms |
| Isolation (Channels to Ground) | 1000 Vrms |
| Input Overvoltage Protection | -15 to 15 V (state 0), -30 to 30 V (state 1) |
| Electrical Connection | 2 x SUB-D 25 connectors |
| Current Consumption | 270 mA @ 5 VDC |
| Module Format | Standard |
| Protection Rating | IP20 |
| Operating Temperature | 0 to 60 °C |
| Storage Temperature | -25 to 70 °C |
| Relative Humidity (Operation) | 10-95% (non-condensing) |
| Weight | 0.34 kg (0.75 lbs) |
| EAN | 3389110726114 |
| Country of Origin | France (FR) |
Certifications
- IEC 1131
- Marine: BV, GL, LR, DNV, RINA, ABS, RMRS
- CE Marked
Key Features
- 16 high-level analog input channels
- Supports current (0-20 mA, 4-20 mA) and voltage (±10 V, 0-10 V, 0-5 V, 1-5 V) inputs
- 12-bit analog-to-digital conversion for precise measurement
- 1000 Vrms isolation between channels and bus/ground
- Fast read cycle time: 3 ms + 3 ms per channel
- Nominal read cycle time: 51 ms
- Measurement error 0.1% of full scale at 25 °C (voltage)
- Input overvoltage protection -30 to 30 V at state 1
- Two SUB-D 25 connectors for electrical connection
- Marine certified (BV, GL, LR, DNV, RINA, ABS, RMRS)
- IP20 protection rating
Installation Notes
Install the module in a TSX Micro or Modicon Premium PLC rack. Connect field wiring using the two SUB-D 25 connectors. Observe input overvoltage limits of -15 to 15 V at state 0 and -30 to 30 V at state 1. Maintain operating temperature between 0 and 60 °C with relative humidity 10-95% (non-condensing). The 1000 Vrms isolation protects both the bus and ground paths. For marine applications, the module holds certifications from all major classification societies.
FAQs
Q1: What input types does the TSXAEY1600 support?
A1: Current inputs (0-20 mA, 4-20 mA) and voltage inputs (±10 V, 0-10 V, 0-5 V, 1-5 V).
Q2: What is the A/D conversion resolution?
A2: 12-bit analog-to-digital conversion.
Q3: What is the isolation rating of this module?
A3: 1000 Vrms between channels and bus, and 1000 Vrms between channels and ground.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...