Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:3704E
Triconex 3704E AI Module | 64-Channel Analog Input
Manufacturer: Invensys Triconex
Product No.: 3704E
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 800g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Introduction
The 3704E Analog Input Module from Triconex provides high-channel-count analog acquisition with Triple Modular Redundant reliability. This versatile module handles 64 single-ended inputs across multiple signal ranges with consistent performance. The 3704E delivers robust signal conditioning for both voltage and current measurements in industrial environments.
Core Specifications
- Brand: Triconex
- Model Identification: 3704E Analog Input Module
- Module Type: TMR Analog Input
- Input Capacity: 64 single-ended channels
- Voltage Ranges: 0-5V or 0-10V with +6% tolerance
- Current Input: 0-20mA with selectable shunts
- Scan Speed: 75 millisecond update rate
- Isolation: Non-isolated input design
Signal Performance
- Resolution: 12-bit analog-to-digital conversion
- Accuracy: Better than 0.25% Full Scale Range
- Temperature Stability: 0° to 60°C operating range
- Input Impedance: 30 MΩ minimum DC resistance
- Off-State Resistance: 30 MΩ typical leakage
- Overvoltage Protection: 150 VDC/115 VAC continuous
Input Configuration
- Wiring Scheme: 64 single-ended input points
- Voltage Options: 0-5V or 0-10V range selection
- Current Measurement: 0-20mA with resistor shunts
- Shunt Values: 250Ω for 5V, 500Ω for 10V ranges
- Channel Type: Non-isolated single-ended inputs
- Signal Compatibility: Standard industrial signals
Noise Performance
- Low Frequency: -1 dB rejection @ 8Hz
- Power Line: -12 dB rejection @ 60Hz
- Harmonic Rejection: -18 dB @ 120Hz
- Channel Separation: 200 kΩ leg-to-leg isolation
- Common Mode: Not applicable for single-ended inputs
Conversion Specifications
- Update Time: 75 milliseconds for full channel scan
- Resolution: 12-bit (4096 count) conversion
- Accuracy Class: <0.25% FSR across temperature
- Signal Handling: Programmable input ranges
Frequently Asked Questions
- What voltage ranges are supported?
0-5V and 0-10V voltage inputs with +6% overrange capability.
- How many input channels does the module have?
64 single-ended analog input channels in non-isolated configuration.
- What is the module's conversion resolution?
12-bit resolution providing 4096 discrete measurement steps.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...