Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:6ES7431-7QH00-0AB0
Siemens 6ES7431-7QH00-0AB0 | 16 AI Thermocouple Pt100 Module
Manufacturer: Siemens
Product No.: 6ES7431-7QH00-0AB0
Product Type: Analog Input Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Siemens 6ES7431-7QH00-0AB0 SIMATIC S7-400 Analog Input Module
Product Overview
Siemens 6ES7431-7QH00-0AB0 is a SIMATIC S7-400 analog input module SM 431 with 16 isolated analog inputs. Features 16 bit resolution with alarm and diagnostics functions. Supports voltage, current, resistor, thermocouple, and Pt100/Pt1000/Ni100/Ni1000 input ranges. Isolated between channels and backplane bus. Ideal for high density analog signal acquisition.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Siemens |
| Model | 6ES7431-7QH00-0AB0 |
| Series | SIMATIC S7-400 |
| Type | Analog Input SM 431 |
| Analog Inputs | 16 isolated (8 for resistance) |
| Resolution | 16 bit |
| Load Voltage | 24V DC |
| Input Current from L+ | 400 mA max |
| Backplane Current | 700 mA max at 5V DC |
| Power Loss | 4.5 W typical |
| Voltage Ranges | ±25mV to ±10V, 1 to 5V |
| Current Ranges | ±5mA to ±20mA, 0 to 20mA, 4 to 20mA |
| Thermocouple Types | B, E, J, K, L, N, R, S, T, U |
| RTD Types | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000 |
| Resistor Ranges | 0 to 48, 150, 300, 600, 6000 Ohm |
| Conversion Time | 6 / 20.1 / 23.5 ms |
| Integration Time | 2.5 / 16.7 / 20 ms |
| Shielded Cable Length | 200m max (50m for TC and ≤80mV) |
| Isolation | 2120V DC bus to analog section |
| Dimensions W x H x D | 25 x 290 x 210 mm |
| Weight | 500 g |
Installation
Install module in SIMATIC S7-400 rack. Connect 24V DC load voltage for 2 wire transmitters. Wire analog signals to front connector. Use shielded cable maximum 200m (50m for thermocouples and ≤80mV ranges). Configure temperature compensation for thermocouples. Set diagnostics and alarm parameters per application.
Features
16 isolated analog inputs with 16 bit resolution. Supports voltage, current, thermocouple, RTD, and resistor inputs. External temperature compensation with Pt100 or compensation socket. Parameterizable characteristic linearization. Fast conversion time 6 ms. Diagnostic alarm and limit value alarm functions. High density 16 channel design in compact 25mm width.
FAQ
Q1: How many analog inputs does this module have?
A1: 16 analog inputs for voltage/current measurement, 8 for resistance measurement. Resolution 16 bit.
Q2: What input types are supported?
A2: Voltage (±25mV to ±10V, 1 to 5V), current (0 to 20mA, 4 to 20mA), thermocouple (B, E, J, K, L, N, R, S, T, U), RTD (Pt100, Pt1000, Ni100, Ni1000), and resistors (0 to 48, 150, 300, 600, 6000 Ohm).
Q3: What is the maximum cable length?
A3: 200m for shielded cable. 50m for thermocouples and input ranges ≤80mV. Use shielded cable for all analog signal wiring.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...