Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:6ES7422-1BH11-0AA0
Siemens 6ES7422-1BH11-0AA0 S7-400 SM 422 16 DO 2A
Manufacturer: Siemens
Product No.: 6ES7422-1BH11-0AA0
Product Type: Digital Output Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 600g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Siemens 6ES7422-1BH11-0AA0 SIMATIC S7-400 SM 422 Digital Output Module
Siemens 6ES7422-1BH11-0AA0 is a SIMATIC S7-400 SM 422 digital output module with 16 isolated 24V DC outputs rated at 2A. Features clocked electronic short-circuit protection and 500V DC isolation. Weight approximately 600 g.
Key Specifications
| Parameter | Value |
|---|---|
| Article No. | 6ES7422-1BH11-0AA0 |
| Product Type | Digital Output Module SM 422 |
| Number of Outputs | 16 |
| Output Voltage | 24V DC (20.4-28.8V) |
| Rated Output Current | 2A per channel |
| Backplane Current (5V) | 160 mA max |
| Load Current (L+ without load) | 30 mA max |
| Power Loss | 5W typical |
| Weight | Approximately 600 g |
Output Specifications
| Parameter | Value |
|---|---|
| Output Current Range | 5 mA min to 2.4A max |
| Residual Current (Signal "0") | 0.5 mA max |
| Output Voltage (Signal "1") | L+ (-0.5V) minimum |
| Load Resistance Range | 24 Ω to 4 kΩ |
| Output Delay | 1 ms max (0 to 1 and 1 to 0) |
| Lamp Load Switching | 10W max |
| Short-Circuit Protection | Clocked electronically (2.8-6A threshold) |
Switching Frequency
| Load Type | Max Frequency |
|---|---|
| Resistive | 100 Hz |
| Inductive | 0.1 Hz |
| Inductive (IEC 60947-5-1, DC13) | 0.2 Hz at 1A / 0.1 Hz at 2A |
| Lamp Load | 10 Hz |
Isolation & Environmental
| Parameter | Value |
|---|---|
| Channel Separation | Yes, in groups of 8 |
| Channels to Backplane | Yes |
| Isolation Test Voltage | 500V DC |
| Total Current per Group | 3A up to 40°C / 2A up to 60°C |
| Cable Length (Shielded) | 1000 m max |
| Cable Length (Unshielded) | 600 m max |
Dimensions
| Parameter | Value |
|---|---|
| Width | 25 mm |
| Height | 290 mm |
| Depth | 210 mm |
FAQs
Q1: What is the rated output current?
A1: 2A per channel with a permissible range of 5 mA to 2.4A.
Q2: Can two outputs be paralleled for higher current?
A2: No, not possible for uprating. Redundant control is possible only within the same group.
Q3: What is the isolation test voltage?
A3: 500V DC with channel separation in groups of 8.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
-
How Does ABB AC500-eCo Cut Machining Automation Costs?
This article explains how the ABB AC500-eCo compact PLC fits discrete machining automation, covering CPU memory ...
-
What Makes GE VersaMax Micro PLC Ideal for Factory Retrofits?
This article reviews the GE VersaMax Micro PLC as a practical retrofit solution for compact factory automation, cover...
-
Is DeltaV S-Series DCS Right for Fine Chemical Skids?
This article reviews the Emerson DeltaV S-Series DCS as a compact control solution for modular fine chemical skids, c...
-
How Does GE RX3i PACSystem Redundancy Improve Oil & Gas Skid Control?
This article explores GE RX3i PACSystem redundant control architecture for oil and gas skid automation. It cover...