Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TSXETG3021
Schneider TSXETG3021 | FactoryCast HMI Web Server Gateway
Manufacturer: Schneider
Product No.: TSXETG3021
Product Type: Gateway Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 922g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Schneider TSXETG3021 is a FactoryCast HMI web server and gateway module for TSX Micro PLC systems. It integrates a GSM/GPRS modem operating at 900/1800 MHz for remote communication. With 32 MB internal memory and support for up to 1 GB Compact Flash or USB storage, this module enables web-based monitoring, control, and diagnostics. Weighing 0.922 kg, it suits remote automation and telemetry applications.
Technical Configuration
This module functions as an Ethernet TCP/IP to Modbus gateway, Modem to Modbus gateway, and Modem to Ethernet TCP/IP router with RAS server capability. It includes 6 discrete inputs and 2 discrete outputs for local signal management. The integrated mini firewall, VPN security, and NAT router provide layered network protection. Web Designer software on CD-ROM enables customizable graphic monitoring interfaces and predefined web pages.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Product Line | FactoryCast HMI Gateway / TSX Micro |
| Part Number | TSXETG3021 |
| Product Type | Web server and gateway module |
| Memory Capacity | 32 MB internal, up to 1 GB CF, up to 1 GB USB |
| Modem Type | GSM/GPRS 900/1800 MHz |
| Web Server Class | Class D20 |
| Rated Supply Voltage | 12 V DC, 24 V DC |
| Supply Voltage Limits | 9…30 V DC |
| Rated Current | 100 mA |
| Ethernet Port | 10BASE-T/100BASE-TX, 2-port RJ45 |
| Serial Link | SUB-D 9 RS232C, 57 kbit/s; RJ45 RS485, 115 kbit/s |
| Max Connected Devices | 31 (serial link) |
| Discrete Inputs | 6 (positive logic) |
| Discrete Outputs | 2 (positive logic) |
| Dimensions (W x H x D) | 73.2 x 151.5 x 116.7 mm |
| Net Weight | 0.922 kg (2.06 lbs) |
| Operating Temperature | 0…60 °C |
| Humidity | 10…95 % without condensation |
| IP Protection | IP20 |
| Mounting | Symmetrical DIN rail, plate |
| Certifications | UL 508, CSA C22.2 No 142, A-Tick, CE |
Installation Guide
Mount the module on a symmetrical DIN rail or mounting plate. Connect 12V DC or 24V DC external power within the 9-30V DC range. Attach the Ethernet cable to the 2-port RJ45 interface and serial devices to the SUB-D 9 or RJ45 ports. Insert a Compact Flash or USB memory stick for extended storage if required. Configure the mini firewall, VPN, and password protection through the web interface before network deployment.
Engineering Advantages
The GSM/GPRS modem enables remote monitoring and control at sites without wired network access. Dual storage options (Compact Flash and USB) support data logging and web page hosting up to 1 GB. The built-in firewall, VPN, and NAT router deliver enterprise-grade security without external hardware. Support for 31 serial devices enables large Modbus networks. Web Designer software simplifies custom interface creation for operators.
Technical FAQs
Q1: What modem frequencies does the TSXETG3021 support?
A1: This module includes a GSM/GPRS modem operating at 900 MHz and 1800 MHz for mobile communication.
Q2: How many devices can connect through the serial link?
A2: The serial link supports a maximum of 31 connected devices via RS485 at 115 kbit/s.
Q3: What security features does this gateway provide?
A3: It includes a configurable mini firewall, VPN security, NAT router, and password protection for web page access.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Diagnose GE PACSystem PLC Faults Fast?
GE PACSystem PLC faults disrupt factory automation and process control. This article explains field-proven diagnosis ...
-
How Does ABB Robot Integration Boost Automotive Throughput?
ABB robot integration helps automotive plants cut material handling stoppages and raise throughput. Success depends o...
-
How Does Bently Nevada Vibration Analysis Catch Faults?
Bently Nevada vibration analysis helps industrial automation teams detect rotating machinery faults early by combinin...
-
How Do GE Edge Gateways Enable Zero-Downtime Data Collection?
GE industrial edge gateways let plants collect real-time PLC and DCS data without stopping production. They read lega...
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...