Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TSXCANCD300
Schneider TSXCANCD300 | CANopen Cable 300m IP20
Manufacturer: Schneider
Product No.: TSXCANCD300
Product Type: CANopen Cable
Product Origin: FR
Payment:T/T, Western Union
Weight: 21700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Schneider TSXCANCD300 is a 300-meter bulk connecting cable for CANopen bus networks. This wiring accessory carries CE marking and IP20 protection for control cabinet installation. The 21.7 kg spool supports long-distance bus runs across large plants and distributed control architectures.
Technical Specifications
| Parameter | Value |
| Part Number | TSXCANCD300 |
| Product Series | CANopen |
| Bus/Network Type | CANopen |
| Product Type | CANopen Cable |
| Accessory Category | Wiring Accessories |
| Accessory Type | Connecting Cable |
| Destination | CANopen Bus |
| Cable Length | 300 m |
| Marking | CE |
| IP Rating | IP20 |
| Product Weight | 21.7 kg |
| Package 1 Dimensions | 32.5 x 40 x 40 cm |
| Package 1 Weight | 21.700 kg |
| Package 2 Quantity | 18 units |
| Package 2 Gross Weight | 402.600 kg |
Installation Guide
Route the TSXCANCD300 cable through cable trays or conduits away from high-voltage power lines. Cut to the required length and terminate with SUB-D9 connectors per CANopen wiring standards. Observe proper shielding and ground the shield at one end only. Maintain IP20 cabinet conditions by sealing all entry points against dust and moisture.
Engineering Advantages
This cable delivers 300 meters of continuous CANopen bus run, eliminating splice points and potential failure nodes across large facilities. CE marking ensures compliance with European standards. The 21.7 kg spool provides manageable handling during long cable pulls. IP20 protection suits standard control cabinet installations.
Technical FAQs
Q1: What is the cable length and bus type?
A1: 300 meters. CANopen bus type. Wiring accessory category. IP20 protection.
Q2: What is the product weight and packaging?
A2: Product weight 21.7 kg. Package 1 dimensions 32.5 x 40 x 40 cm. Package weight 21.700 kg.
Q3: How many units are in the bulk package?
A3: Package 2 contains 18 units. Gross weight 402.600 kg. Dimensions 112 x 80 x 120 cm.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...