Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TSXASY410
Schneider Electric TSXASY410 4 Channel Analog Output
Manufacturer: Schneider
Product No.: TSXASY410
Product Type: Analog Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric TSXASY410 Modicon Analog Output Module
Schneider Electric TSXASY410 | Analog output module for the Modicon Premium and TSX Micro automation platforms. Provides 4 analog output channels with selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 1500 Vrms channel-to-channel and channel-to-bus isolation. Screw terminal block connection. Weight: 0.35 kg (0.77 lb).
Key Features
4 analog output channels. Selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 11-bit + sign analog/digital conversion. 2.5 ms conversion time. 10.25 µA resolution (current), 5.12 mV resolution (voltage). 1500 Vrms isolation between channels and bus. Overload and short-circuit protection. Screw terminal block connection. CE marked. Made in France.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXASY410 |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Analog Output Module |
| Number of Channels | 4 |
| Output Type | Current 0-20 mA, 4-20 mA; Voltage ±10 V |
| Analog/Digital Conversion | 11 bits + sign |
| Conversion Time | 2.5 ms |
| Resolution | 10.25 µA (current); 5.12 mV (voltage) |
| Measurement Error (25°C) | 0.45% FS (±10V); 0.52% FS (0-20mA/4-20mA) |
| Measurement Error (0-60°C) | 0.75% FS (±10V); 0.98% FS (0-20mA/4-20mA) |
| Isolation (Channel to Channel) | 1500 Vrms |
| Isolation (Channel to Bus) | 1500 Vrms |
| Isolation (Channel to Ground) | 500 V |
| Load Impedance (Current) | < 600 Ω (0-20 mA, 4-20 mA) |
| Load Impedance (Voltage) | > 1000 Ω (±10 V) |
| Max Load Inductance | 300 µH |
| Max Load Capacitance | 0.1 µF |
| Output Voltage Limit | ≤ 30 V |
| Current Consumption | 900 mA @ 5V DC |
| Power Supply | 24V DC |
| Power Consumption | 3 W |
| Electrical Connection | Screw terminal block |
| Protection | Overload, short-circuit |
| Dimensions (W x H x D) | 125 x 100 x 40 mm |
| Net Weight | 0.35 kg (0.77 lb) |
| IP Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 10-95% (operation); 5-95% (storage), non-condensing |
| Operating Altitude | 0-2000 m |
| Certifications | CE, UL 508, CSA, IEC 61131-2, GL, ABS, RINA, DNV |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect field wiring via screw terminal block. Use shielded cable for analog signals and connect shields to the designated shield terminals. Observe load impedance limits: <600 Ω for current output, >1000 Ω for voltage output. Maintain IP20 enclosure and pollution degree 2 environment. Ensure operating temperature remains between 0°C and 60°C.
Engineering Advantages
Selectable current or voltage output on each channel provides application flexibility. 1500 Vrms channel-to-channel isolation protects against ground loops and noise. High 11-bit + sign resolution ensures precise analog control. Overload and short-circuit protection safeguard the module and connected equipment. Compact 0.35 kg design saves panel space. Marine certifications (GL, ABS, RINA, DNV) enable use in shipboard and offshore applications.
FAQs
Q1: What output types are available?
A1: Current (0-20 mA, 4-20 mA) and voltage (±10 V).
Q2: What is the isolation rating?
A2: 1500 Vrms between channels and bus, 500 V between channels and ground.
Q3: What is the power consumption?
A3: 3 W at 24V DC supply, with 900 mA current consumption at 5V DC.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can You Restore a DCS Controller Without Downtime?
This article explains field-proven backup and recovery workflows for ABB AC800M DCS controllers. It covers pre-backup...
-
What Makes Live Honeywell Transmitter Replacement Safe?
This article explains how industrial automation teams can replace aging Honeywell transmitters online without a full ...
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
