Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140NOE35100
Schneider Electric 140NOE35100 Modicon Quantum Fiber Optic
Manufacturer: Schneider
Product No.: 140NOE35100
Product Type: Ethernet Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The 140NOE35100 stands as a specialized fiber optic Ethernet communication module within the Schneider Electric Modicon Quantum series. Engineered for environments prone to electromagnetic interference, this module utilizes 10BASE-FL connectivity to ensure isolated and secure data transmission over long distances. By facilitating high-speed communication within a local backplane, it serves as a critical gateway for PLC data exchange, providing a robust backbone for industrial automation architectures that demand zero signal degradation.
Core Technical Advantages
This module features a unique dual-port 10BASE-FL configuration using ST-style connectors, specifically designed for fiber optic media. The hardware is treated with a professional-grade conformal coating, protecting internal circuitry against humidity, dust, and chemical contaminants. It is built to operate seamlessly at altitudes up to 2,000 meters, supporting global deployment in various industrial climates. Its flexible power architecture allows for integration into systems ranging from 24 VDC to 230 VAC, ensuring universal compatibility across the Quantum product line.
Technical Specifications
| Manufacturer | Schneider Electric |
| Model / Part No. | 140NOE35100 |
| Communication Ports | 2 x 10BASE-FL (ST-Style Fiber) |
| Bus Current | 1.0 A |
| Protection | Conformal Coating |
| Operating Temp | 0 to 60°C |
Installation & Maintenance
The module must be installed exclusively in a local backplane to ensure proper bus communication and timing. When connecting fiber optic cables, ensure the ST-style connectors are clean and fully seated; a light audible click confirms a secure link. Weighing approximately 0.45 kg, the unit is easily handled but requires careful alignment with the backplane pins to prevent mechanical damage. Periodic inspection of the fiber ports is recommended to prevent signal loss caused by dust accumulation on the optical lenses.
Engineering Advantages
The unit offers superior noise immunity compared to copper-based Ethernet, making it the preferred choice for motor control centers or facilities with high-frequency noise. The conformal coating provides an extra layer of defense in "harsh" environments, extending the lifecycle of the 140NOE35100 significantly. With full compliance for UL, CE, and CSA standards, this module meets the safety and insurance requirements for high-stakes infrastructure and manufacturing projects.
Technical FAQs
Q1: Can I use standard RJ45 copper cables with the 140NOE35100?
A1: No, this module is specifically designed for fiber optic media using ST-style 10BASE-FL connections and does not support copper cabling.
Q2: Does this module support remote I/O backplanes?
A2: No, the hardware is designed strictly for support in local backplanes only to maintain communication speed and integrity.
Q3: What is the benefit of the conformal coating on this specific model?
A3: The coating protects the PCB from corrosion and moisture, allowing the module to maintain a 95% humidity tolerance without the risk of electrical short-circuits.
Additional Specifications
- Gray
- Black
- White
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...