Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140ACI04000
Schneider Electric 140ACI04000 16-Channel Analog Input Module
Manufacturer: Schneider
Product No.: 140ACI04000
Product Type: Analog Input Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 433g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric 140ACI04000 Analog Input Module
The Schneider Electric 140ACI04000 is a high-density analog input module for Modicon Quantum systems. This 16-channel module delivers precise current signal acquisition with robust industrial performance and comprehensive diagnostics.
Key Technical Specifications
- Brand: Schneider Electric
- Model: 140ACI04000
- Product Type: 16-Channel Analog Input for Modicon Quantum
- Number of Inputs: 16 differential channels
- Input Ranges: 0-20 mA, 0-25 mA, and 4-20 mA
- Resolution: Up to 0-25000 counts for high precision
- Absolute Accuracy: ±0.125% of full scale
- Update Time: 15 ms for all channels
Performance & Protection Features
- Isolation: 1780V AC for 60 seconds between channels and bus
- Common Mode Rejection: >90 dB at 60 Hz for superior noise immunity
- Diagnostics: Built-in broken wire detection for 4-20 mA loops
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Certifications: UL 508, CSA, FM Class 1 Division 2, cUL
Module Indicators & Installation
- LED indicators for bus communication (green) and external fault (red)
- 16 green LEDs show active channels, 16 red LEDs indicate channel faults
- Standard format module for Quantum PLC rack mounting
- Bus current requirement: 360 mA
- Power dissipation: 5 W
Shipping & Packaging
- Package includes: 1 x 140ACI04000 module
- Package dimensions: 12.20" x 6.50" x 1.81" (31.0 x 16.5 x 4.6 cm)
- Shipping weight: 15.3 oz (433 g)
- Shipping options: FedEx, UPS, DHL
Frequently Asked Questions
- What current signals does this module accept? It accepts 0-20 mA, 0-25 mA, and 4-20 mA current signals.
- How many input channels are available? The module provides 16 differential input channels.
- What is the update time for all channels? All 16 channels update within 15 milliseconds.
Additional Specifications
- Gray
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...
