Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:V18345-1004210001
Positioner V18345-1004210001 ABB | 4-20mA
Manufacturer: ABB
Product No.: V18345-1004210001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The V18345-1004210001 is an electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART FSK communication, ATEX EEx nA II T6 protection, and fail-freeze output. Aluminum IP65/NEMA 4X housing. Weight: 1.7 kg. Certified for SIL2 safety loops.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-1004210001 |
| Manufacturer | ABB |
| Type | Electro-Pneumatic Positioner (TZIDC) |
| Input Signal | 4–20 mA two-wire, max 25 mA / 30 V |
| Min Input Current | 3.4 mA (without feedback), start from 3.8 mA |
| Communication | HART 5.1, FSK module, LKS local connector |
| Explosion Protection | ATEX EEx nA II T6 (Zone 2) |
| Output / Safe Position | Fail freeze (single or double acting) |
| Output Range | 0–6 bar (0–90 psi) |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Air Capacity (1.4 bar) | 5.0 kg/h = 3.9 Nm³/h = 2.3 scfm |
| Air Capacity (6 bar) | 13 kg/h = 10 Nm³/h = 6.0 scfm |
| Air Quality | DIN/ISO 8573-1 Class 3 (5 µm, 5 mg/m³, oil 1 mg/m³) |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | 2 threads 1/2-14 NPT or M20x1.5 |
| Screw Terminals | Max 1.0 mm² (options) / 2.5 mm² (analog signal) |
| Digital Input | 24 V DC (12–30 V DC), max 4 mA |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Load Voltage (20 mA) | 8.7 V DC (non-Ex) / 9.7 V DC (intrinsically safe) |
| Impedance (20 mA) | 435 Ω (non-Ex) / 485 Ω (intrinsically safe) |
| Angle of Rotation | 25–120° (rotary, optional 270°); 25–60° (linear) |
| Travel Limit | 0–100%, min range >20% |
| Travel Time Prolongation | 0–200 seconds per direction |
| Characteristic Deviation | ≤0.5% |
| Tolerance Band | 0.3–10% adjustable |
| Dead Band | 0.1–10% adjustable |
| Resolution | >4000 steps |
| Sample Rate | 20 ms |
| Temperature Influence | ≤0.5% per 10°C |
| Vibration Influence | ≤±1% up to 10 g and 80 Hz |
| Seismic Compliance | DIN/IEC 68-3-3 Class III |
| Ambient Temperature | -40°C to +85°C |
| Humidity (Operational) | 95% annual average, condensation permissible |
| Humidity (Transport/Storage) | 75% annual average, non-condensing |
| Safety | SIL2 safety loops |
| Approvals | ATEX, FM, CSA, IECEx |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Integral mounting ready. Mechanical position indicator provides visual feedback. Mounting orientation has no effect on performance.
Air Supply
Use instrument air free of oil, water, and dust per DIN/ISO 8573-1 Class 3: max particle 5 µm, density 5 mg/m³, oil 1 mg/m³, dew point 10 K below operating temperature. Do not exceed actuator max operating pressure.
Hazardous Area Installation
ATEX EEx nA II T6 (Zone 2) approved. Ambient temperature limits: T4 -40°C to +85°C, T5 -40°C to +65°C, T6 -40°C to +50°C. Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.
Engineering Advantages
Fail-Freeze Safety
On electrical power failure, the actuator blocks in its last position (fail freeze). Ensures process continuity and safe operation in critical applications. Certified for SIL2 safety loops.
ATEX Zone 2 Protection
ATEX EEx nA II T6 certification enables installation in Zone 2 hazardous areas. Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.
Precise Valve Control
Resolution >4000 steps with 20 ms sample rate. Characteristic deviation ≤0.5%. Freely configurable characteristic curves with 20 reference points. HART FSK communication for remote diagnostics.
Technical FAQs
Q1: What is the fail-safe behavior on electrical power failure?
A1: Fail freeze. The actuator blocks in its last position on loss of electrical power. Air is vented from the actuator or the actuator is blocked.
Q2: What explosion protection does this model provide?
A2: ATEX EEx nA II T6 (Zone 2). Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6.
Q3: What communication protocol does this positioner use?
A3: HART 5.1 via FSK module over the 20 mA signal line. Also supports LKS local communication interface.
Additional Specifications
- Silver
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...