Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1734-IM4
POINT I/O Digital AC Input Module Allen-Bradley 1734-IM4
Manufacturer: Allen-Bradley
Product No.: 1734-IM4
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 30g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1734-IM4 is a POINT I/O 1734 series digital AC input module with 4 input channels labeled 0 to 3. It operates at 220V AC nominal with an on-state voltage range of 159 to 264V AC. Weighing approximately 30.9 g (1.09 oz), this open-style module mounts on a DIN rail and requires the mounting base keyswitch in position 8.
Technical Configuration
This module provides 4 non-isolated sink inputs in one group with individual status indicators per channel. Each input has a 20 ms hardware filter plus a programmable digital filter from 1 to 65.535 ms in 1 ms increments. Status indicators show network state, module state, and individual input states. The module accepts 22 to 14 AWG solid or stranded copper wire and measures 2.21 x 0.47 x 2.97 inches.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IM4 |
| Series | POINT I/O |
| Module Type | Digital AC Input Module |
| Inputs | 4 (1 group of 4), non-isolated sink |
| Input Voltage | 220V AC nominal at 60 Hz |
| On-State Voltage Range | 159-264V AC |
| On-State Current | 6.2 mA @ 159V AC; 10.2 mA @ 264V AC |
| Delay Time (ON-OFF/OFF-ON) | 20 ms hardware filter + 1-65.535 ms programmable digital filter |
| Nominal Input Impedance | 22.3 kΩ |
| POINTBus Current | 75 mA at 5V DC |
| Power Dissipation | Max 0.80 W at 264V AC |
| Thermal Dissipation | Max 2.73 BTU/hour at 264V AC |
| Isolation Voltage | 240V continuous (field to system) |
| Key Switch Position | 8 |
| Wire Size | 22-14 AWG copper |
| Dimensions | 2.21 x 0.47 x 2.97 in |
| Weight | 30.9 g (1.09 oz) |
Installation Guide
Rotate the mounting base keyswitch to position 8 before installing the module. Mount on a DIN rail and wire field connections with 22 to 14 AWG solid or stranded copper wire. Verify the AC supply delivers 220V AC at 60 Hz within the 159-264V AC on-state range. Configure the programmable digital filter between 1 and 65.535 ms according to application noise requirements. Confirm 240V continuous isolation between field side and system before energizing.
Engineering Advantages
This module provides 4 AC input channels in a compact 30.9 g package, conserving panel space in distributed I/O architectures. The programmable digital filter from 1 to 65.535 ms allows noise rejection tuning without external hardware. Individual status indicators per channel accelerate fault diagnosis. The 22.3 kΩ input impedance and 240V continuous isolation protect the POINT bus from field transients. The wide 159-264V AC range tolerates supply variations in industrial power systems.
Technical FAQs
Q1: How many inputs does the 1734-IM4 provide?
A1: This module provides 4 non-isolated sink inputs in one group, labeled 0 to 3, each with an individual status indicator.
Q2: What filter options are available on this module?
A2: Inputs include a 20 ms hardware filter plus a programmable digital filter from 1 to 65.535 ms in 1 ms increments.
Q3: What isolation does the 1734-IM4 provide?
A3: The module offers 240V continuous isolation between the field side and the system for protection against hazardous voltages.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...