Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:MTL5573
MTL Instruments MTL5573 | Zone 0 Temperature Transmitter
Manufacturer: MTL
Product No.: MTL5573
Product Type: Temperature Transmitter
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The MTL5573 Temperature Converter from MTL Instruments provides intrinsically safe signal conditioning for hazardous area temperature monitoring. This single-channel unit converts RTD and thermocouple inputs to 4-20mA outputs with exceptional 120dB common mode rejection. The MTL5573 features early burnout detection and flexible configuration for reliable process control.
Technical Specifications
- Manufacturer: MTL Instruments
- Model: MTL5573 Temperature Converter
- Channels: Single channel operation
- Hazardous Rating: Zone 0, IIC, Division 1 Groups A-D
- Output: 4-20mA into 600Ω maximum
- Response Time: 500ms typical
- Power Consumption: 50mA at 24V
Signal Performance
- RTD Excitation: 200μA nominal current
- CMRR: 120dB @ 240V, 50/60Hz
- SMRR: 40dB @ 50/60Hz
- CJC Error: ≤1.0°C for thermocouples
- Output Compliance: NAMUR NE43 standard
Safety Features
- Sensor Failure: Upscale/downscale/off options
- Early Burnout: >50Ω resistance detection
- Lead Resistance: 600Ω with safety enabled
- Maximum Voltage: Um=253V RMS or DC
- Certification: Full hazardous area approval
Configuration & Monitoring
- Software: MTL PCS45 with PCL45USB interface
- CJC Control: Selectable ON/OFF for thermocouples
- Alarm Indication: Green EBD, Yellow alarm LEDs
- Power Dissipation: 1.2W at 24V operation
Application Features
- Input Types: RTD and thermocouple compatible
- Output Range: 4-20mA standard process signal
- Isolation: High CMRR for noisy environments
- Diagnostics: Comprehensive failure detection
- Flexibility: Multiple failure mode responses
Frequently Asked Questions
- What is the common mode rejection?
120dB rejection at 240V for 50/60Hz interference.
- How is early burnout detected?
Triggered when loop resistance increases beyond 50Ω.
- What configuration software is needed?
MTL PCS45 software with PCL45USB interface for PC setup.
For pricing and technical support, contact us at sale@etowonauto.com
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can VersaMax PLC Expansion Fix Auto I/O Bottlenecks?
This article examines GE Fanuc VersaMax PLC expansion for automotive assembly I/O constraints. A 12-station SUV plant...
-
Is Your Legacy DCS Costing You 35% More Downtime Each Year?
This technical article presents a data-driven strategy for migrating end-of-life Emerson DCS to ABB 800F systems with...
-
What Is the Real Hourly Cost of Automation Downtime?
Industrial automation downtime creates severe financial losses, with PLC and DCS hardware failures causing 62% of unp...
-
Does Bently Nevada & PLC Integration Cut Refinery Downtime?
This article details a field-validated Bently Nevada 3500 and Allen-Bradley ControlLogix integration for oil and gas ...
-
Is Your Plant Ready for ABB-GE Fanuc Hybrid Control?
This article examines a hybrid ABB DCS and GE Fanuc PLC architecture for aging metallurgical lines, delivering 99.8% ...
-
Can Bently Nevada Integrate with Emerson DCS?
This article explores how Bently Nevada 3500 TSI and Emerson DeltaV DCS integration delivers measurable predictive ma...
