Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:MTL5046
MTL Instruments MTL5046 Isolating Driver
Manufacturer: MTL
Product No.: MTL5046
Product Type: Isolating Driver
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
MTL5046 Isolating Driver
The MTL5046 from MTL Instruments provides safe signal isolation for hazardous areas. This single-channel driver converts 4-20mA control signals to drive loads in explosive atmospheres. It offers reliable performance with compact dimensions and light weight.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5046
- Product Type: Isolating Driver
- Channels: 1 channel
- Unit Weight: 110 grams
- Dimensions: 10.4 x 1.6 x 11 cm (HxWxD)
- Supply Voltage: 20 to 35V DC
Signal Specifications
- Input Signal: 4 to 20mA standard range
- Over-range Capability: 1 to 24mA extended range
- Digital Bandwidth: 500Hz to 10kHz
- The driver handles both analog and digital signal types
- It provides precise signal conversion with high accuracy
Hazardous Area Certification
- Load Location: Zone 0, IIC, T4-T6 with certification
- Division Rating: Division 1, Group A hazardous location
- The unit ensures intrinsic safety for connected field devices
- It provides complete isolation between safe and hazardous areas
Physical Characteristics
- Weight: 110 grams for easy handling
- Dimensions: 10.4 cm height x 1.6 cm width x 11 cm depth
- Compact design saves valuable panel space
- Lightweight construction simplifies installation
Power & Indicators
- Supply Range: 20 to 35V DC operating voltage
- Status Indication: Green LED for power monitoring
- The driver requires minimal power for operation
- Clear visual feedback ensures quick status checks
Frequently Asked Questions
-
What signals does the MTL5046 accept?
It accepts 4-20mA analog signals with 1-24mA over-range capability. -
What is the digital bandwidth?
The driver handles digital signals from 500Hz to 10kHz. -
Where can I install the load device?
Loads can be in Zone 0, IIC, T4-T6 areas with proper certification. -
How much does the unit weigh?
The isolating driver weighs only 110 grams for easy installation.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Is the Real Hourly Cost of Automation Downtime?
Industrial automation downtime creates severe financial losses, with PLC and DCS hardware failures causing 62% of unp...
-
Does Bently Nevada & PLC Integration Cut Refinery Downtime?
This article details a field-validated Bently Nevada 3500 and Allen-Bradley ControlLogix integration for oil and gas ...
-
Is Your Plant Ready for ABB-GE Fanuc Hybrid Control?
This article examines a hybrid ABB DCS and GE Fanuc PLC architecture for aging metallurgical lines, delivering 99.8% ...
-
Can Bently Nevada Integrate with Emerson DCS?
This article explores how Bently Nevada 3500 TSI and Emerson DeltaV DCS integration delivers measurable predictive ma...
-
Why 38% of Refinery Shutdowns Start with Aging PLCs?
This article examines how genuine GE Fanuc PLC spare parts and Bently Nevada TSI monitoring cards enable Industry 4.0...
-
Can Integrated DCS-PLC Solve Food Production Inconsistency?
This article examines how integrating Emerson DeltaV DCS with Allen‑Bradley PLC resolves food manufacturing control p...