ICS Triplex T9402 Digital Input Module 16 Channel 24V

Only 6 units left
  • Manufacturer: ICS Triplex

  • Product No.: T9402

  • Product Type: Digital Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 340g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Day Return Policy · 12-Month Warranty
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Description

Product Overview

The ICS Triplex T9402 is a 16‑channel isolated digital input module for the Trusted TMR system. It accepts 0–32 Vdc inputs at 6.5 mA per channel, making it suitable for field contact monitoring, switch status, and limit sensing in safety‑critical applications. The module delivers deterministic scan times configurable for simplex (0.924 ms), dual (1.676 ms), or triple (2.453 ms) redundancy configurations.

Core Advantages

Flexible Redundancy Configuration

Supports simplex, dual, or triple input configurations with predictable scan times. Choose the redundancy level that matches your safety integrity requirements—0.924 ms for simplex, 1.676 ms for dual, or 2.453 ms for triple.

Fully Isolated Channels

All 16 channels are galvanically isolated, protecting the backplane from field transients and ensuring reliable operation in noisy industrial environments.

Low Power Consumption

Draws only 4.0 W (260 mA at 24V), minimising heat generation and reducing chassis cooling requirements.

Specifications

Parameter Value
Supply Voltage 18–32 Vdc
Maximum Current 260 mA
Power Consumption 4.0 W
Heat Dissipation 4.0 W (13.6 BTU/hr)
Input Voltage Range 0–32 Vdc
Input Current 6.5 mA
Number of Channels 16 (isolated)
Scan Time (Simplex) 0.924 ms
Scan Time (Dual) 1.676 ms
Scan Time (Triple) 2.453 ms
Certifications ATEX, IECEx, HazLoc, Ordinary Location
Weight 340 g

Installation Tips

Redundancy Planning

Select simplex, dual, or triple configuration based on your SIL requirement and available slots. Triple configuration uses three T9402 modules for 2‑out‑of‑3 voting. Scan time scales linearly with redundancy level.

Input Wiring

Connect field devices (pushbuttons, limit switches, proximity sensors) to the isolated input terminals. Each channel accepts 0–32 Vdc at 6.5 mA. Use shielded cables for long field runs to minimise noise pickup.

Channel Isolation

Each input is independently isolated from the backplane and from other channels. This prevents ground loops and protects the system from field wiring faults.

Why Choose T9402?

Delivers 16 isolated digital inputs in a compact, low‑power package. The deterministic scan times allow precise timing for safety logic execution. Supports flexible redundancy configurations to match any SIL level. Certified for hazardous areas and compatible with all ICS Triplex Trusted chassis. Ideal for emergency shutdown, fire & gas, and burner management systems.

FAQs

Q1: What determines the scan time I should use?
A1: The scan time depends on your system's redundancy configuration. Simplex (0.924 ms) for single modules, dual (1.676 ms) for redundant pairs, and triple (2.453 ms) for full TMR with 2‑out‑of‑3 voting.

Q2: Can I mix input voltage levels on different channels?
A2: Yes. Each channel accepts any voltage from 0 to 32 Vdc independently, thanks to full channel‑to‑channel isolation.

Q3: What is the 6.5 mA input current used for?
A3: The 6.5 mA is the wetting current that flows through the field contact. It helps clean switch contacts and ensures reliable low‑resistance connections, especially for dry contact inputs.

Scalar (V/f)

Vector

AC-powered

  • Confirm the exact model, part number, and specifications before ordering.
  • Ensure compatibility with your current machinery or control systems.
  • Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
  • Review delivery options, lead times, and shipping requirements.
  • Follow manufacturer instructions and best practices during installation.

In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.

Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.

For more details, please review our Shipping & Return Policy.

View Product Details

ENSURE RELIABLE MACHINERY PERFORMANCE

Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.