Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC697PWR724
IC697PWR724 GE Fanuc 90-70 24VDC Power Module 90W New
Manufacturer: General Electric
Product No.: IC697PWR724
Product Type: Power Supply Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1750g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC697PWR724 is a 90-Watt rack-mounted power supply module engineered for Series 90-70 programmable logic controllers and VME-compatible integrated racks. Operating on a nominal 24 VDC input, this module weighs approximately 1.75 kg (3.86 lbs) and mounts directly onto the leftmost slot of the chassis via a 48-pin backplane connector. It delivers highly regulated triple DC output rails to support local processing logic or dual-rack expansions via interconnection cabling, provided the combined system draw remains within safe load limitations.
Core Technical Advantages
- Dual-Rack Power Flexibility: Capably drives a single-rack configuration or distributes multi-rail DC outputs across two interconnected racks simultaneously via cable.
- High-Current Output Density: Delivers clean, logic-level sequencing power across three separate voltage lines (5V, 12V, and -12V) to easily sustain intensive industrial I/O architectures.
- Industrial Power Protection: Equipped with active overvoltage and overcurrent safeguards, alongside a 22-Joule inrush energy threshold, to completely protect internal electronics from hazardous line surges.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Model Part No. | GE Fanuc / IC697PWR724 |
| Gross Weight | 1.75 kg (3.86 lbs) |
| Nominal Rated Voltage | 24 VDC |
| Input Voltage Window | 18 to 32 VDC |
| Input Power Load | 160 Watts maximum |
| Input Inrush Energy | 22 Joules maximum |
| Regulated DC Outputs | 5 VDC at 26 A / 12 VDC at 4 A / –12 VDC at 2 A |
| Total Output Wattage | 90 Watts maximum combined output load |
| Ride-Through Duration | 10 milliseconds minimum at 20 VDC input |
| 5V Overvoltage Ceiling | 5 VDC overvoltage protection limit |
| System Compatibility | VME compatible / 48-pin backplane mounted connector |
| Operating Temperature | 0 to 60 °C (Derating required if environmental limits are exceeded) |
Installation & Engineering Guide
- Slot Placement: Firmly slide the 1.75 kg unit into the leftmost slot of the Series 90-70 or VME rack. Ensure the 48-pin backplane connector engages fully with the receiver before securing all terminal mounting hardware.
- Dual-Rack Expansion: When powering a secondary chassis, bridge the systems using the designated interface cable. Calculate the continuous draw of both racks to verify the combined total stays strictly beneath the 90-Watt power budget.
- Thermal Constraints: Monitor the surrounding environment to keep ambient temperatures within the 0 to 60 °C window. If field conditions breach 60 °C, system capacity derating must be applied to maintain baseline operational safety.
Technical FAQs
Q1: What are the specific current output limits for the DC power rails?
A1: The module outputs 5 VDC at 26 A, 12 VDC at 4 A, and –12 VDC at 2 A, provided the concurrent combined load does not cross the 90-Watt threshold.
Q2: How does the IC697PWR724 manage momentary field voltage drops?
A2: It provides an integrated 10-millisecond ride-through time at 20 VDC input, keeping system log sequencing and processor logic running steadily during quick brownouts.
Q3: Can this 24 VDC module accept unstable industrial inputs safely?
A3: Yes. It works reliably across a broad input voltage range of 18 to 32 VDC, dynamically smoothing out typical battery bank shifts and raw generator fluctuations.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...
-
Is Your SME Process Factory Overpaying for Industrial Automation?
This article provides a data-driven guide for SME process factories to deploy right-sized DCS solutions without overs...
-
Why Did a $420,000 Shutdown Happen Despite CPU Redundancy?
This article presents 15 years of field-tested evidence showing how hidden single points of failure cause unplanned s...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...