Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC697MDL340
IC697MDL340 GE Intelligent Platforms Output Module 120V
Manufacturer: General Electric
Product No.: IC697MDL340
Product Type: Discrete Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
IC697MDL340 GE Fanuc Discrete Output Module – 16 Points 120VAC
The GE Fanuc IC697MDL340 is a 16-point discrete output module for the Series 90-70 PLC platform. Rated at 120 VAC. 16 output points divided into four isolated groups of four points each.
Product Information
| Brand | GE Intelligent Platforms / GE Fanuc |
| Series | Series 90-70 |
| Part Number | IC697MDL340 |
| Product Type | Output Module |
| Rated Voltage | 120 VAC |
| Outputs | 16 |
| Isolation Groups | 4 (four points per group) |
| Frequency | 47-63 Hz |
| DC Power | No |
| AC Power | Yes |
| LED Indicators | Yes |
| Weight | 0.5 kg |
Electrical Specifications
| Output Voltage Range | 85 to 132 VAC |
| Output Current Per Point | 2 A max |
| Output Current Per Group | 4 A max |
| Inrush Current | 10x rated current |
| On Response Time | 1 ms max |
| Off Response Time | 1/2 cycle |
| Leakage Current | 1.5 mA max |
Power Requirements
| 5V Bus Current | 0.25 A |
| Fuse Rating | 10 A per group |
Features
- 16 digital output points in 4 isolated groups of 4 points each
- Rated 120 VAC, operating range 85 to 132 VAC
- 2 Amps continuous per point, 4 Amps per group
- 10x inrush current capacity for incandescent and inductive loads
- Each group separately fused with 10 Amp fuses
- LED indicators for point on/off status and fuse status
- Mechanical keying for correct module replacement
- Configuration without jumpers or DIP switches
- Compatible with motor starters, solenoids, and indicators
- Works with most Size 4 contactors
FAQs
Q1: How many output points does the IC697MDL340 have?
A1: 16 digital output points arranged in four isolated groups of four points each.
Q2: What is the maximum current per point and per group?
A2: 2 Amps max per point, 4 Amps max per group. Each group is separately fused with a 10 Amp fuse.
Q3: What is the rated voltage and frequency?
A3: 120 VAC rated voltage with operating range 85 to 132 VAC at 47 to 63 Hz.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Does ABB Marine PLC Survive 50g Vibration at Sea?
This article examines how Emerson Kappa DCS and ABB Marine PLC solve offshore chemical vessel control pain points—95%...
-
Can Genuine Parts Cut Downtime by 70%?
Aging PLC and DCS hardware causes most unplanned downtime. This guide quantifies failure risks, compares original ver...
-
Can Cross-Brand PLC-DCS Integration Solve Smart Port Data Silos?
This technical article examines how cross-brand integration of GE Fanuc RX7i PLCs, Allen‑Bradley HMIs and Emerson DCS...
-
Can Mixed-Vendor PLC and DCS Systems Work Seamlessly?
This article examines the operational impact of heterogeneous industrial control systems, quantifying downtime losses...
-
Zero-Downtime PLC Migration: Upgrade Without Stopping?
Aging GE Fanuc PLCs pose significant operational risks due to part shortages and failing IoT compatibility. This arti...
-
Why Integrate Bently Nevada Vibration Monitoring with Emerson AMS?
This technical article examines how integrating Emerson AMS asset management software with Bently Nevada vibration se...