Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:3500/61-04-02
Bently Nevada 3500/61-04-02 Isolated TC Monitor ATEX
Manufacturer: Bently Nevada
Product No.: 3500/61-04-02
Product Type: Temperature Monitor
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Bently Nevada 3500/61-04-02 monitors up to six thermocouple inputs. It features isolated I/O with external terminations and recorder outputs.
- Bently Nevada USA manufacture. 3500/61-04-02 uses TC isolated I/O module with external terminations.
- ATEX/IECEx/CSA (Class 1, Zone 2) approval included.
- 500 Vdc system isolation. 250 Vdc channel isolation.
- Monitor uses one front slot. I/O uses one rear slot.
Technical Specifications
- Brand: Bently Nevada | Model: 3500/61-04-02
- Inputs: 1-6 TC signals. 10 MΩ impedance per lead.
- Power: 9 watts nominal.
- TC support: Types E, J, K, T. -256°F to +2498°F.
- Type E note: Above +35°C ambient, range reduces to -60°C to +1000°C.
- Output: +4 to +20 mA recorder. Load 0-600 Ω.
- Resolution: 0.3662 µA/bit. ±0.15% accuracy.
- Accuracy: ±1°C at 25°C (external termination isolated).
Environmental
- Operating: -30°C to +65°C.
- Storage: -40°C to +85°C.
- Isolation: 500 Vdc system, 250 Vdc channel.
Dimensions
- Monitor: 241.3 x 24.4 x 241.8 mm. 0.91 kg.
- I/O module: 241.3 x 24.4 x 99.1 mm. 0.45 kg.
Installation
- Install monitor in front slot. Install I/O in rear slot.
- Connect wiring to external terminations.
- Configure using 3500 software. Verify LEDs.
Includes
- 1 x 3500/61-04-02 monitor module
- 1 x isolated TC I/O module with external terminations
- Documentation
Shipping
- FedEx, UPS, DHL worldwide.
- Expedited shipping available.
- Secure packaging.
FAQ
Q: Works with RTD sensors?
A: Yes, 3500/61-04-02 supports RTD with isolated configuration.
Q: Isolation rating?
A: 500 Vdc system. 250 Vdc channel to channel.
Q: Best accuracy?
A: ±1°C at 25°C with external termination isolated.
Additional Specifications
- White
- Blue
- Silver
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...
-
How Does ABB Fieldbus Cut Industrial Automation Wiring Costs?
ABB fieldbus instruments reduce cable costs by 40-55% and enable real-time DCS diagnostics, yet 62% of faults stem fr...
-
Can Wireless Gas Detection Fix Hard-to-Reach Plant Blind Spots?
This article reviews how the Honeywell Universal Transmitter enables wireless gas detection in hard-to-reach hazardou...
-
How Does GE Cimplicity HMI Tuning Boost Operator Performance?
This article explains how targeted GE Cimplicity HMI tuning improves operator performance in large control rooms. It ...
-
Why Do Continuous Process Plants Need ABB Redundant Networks?
This article examines practical ABB redundant control network design for continuous process plants, covering dual sta...