Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC697BEM741
IC697BEM741 GE Fanuc Series 90-70 FIP Bus Controller
Manufacturer: General Electric
Product No.: IC697BEM741
Product Type: Controller Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 1810g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The IC697BEM741 is a high-reliability FIP / WorldFIP (EN50170) Fieldbus Controller module designed for the GE Fanuc Series 90-70 programmable logic controller (PLC) platform. Operating as a single-slot Bus Expansion Module, this interface card establishes a deterministic network gateway capable of managing up to 128 connected field devices at a data communication speed of 1.0 Megabits per second (Mbps). Weighing approximately 4.0 pounds (1.81 kg), it provides heavy-duty central processing units with decentralized remote input/output capability, maximizing network reach across large industrial automation plants.
Core Technical Advantages
-
Detailed Suffix Logic Breakdown:
- IC697: Confirms native form-factor integration with the GE Fanuc Series 90-70 VME backplane ecosystem.
- BEM: Designates a dedicated Bus Expansion Module engineered for specialized network communication.
- 741: Specifies the operational hardware variant for the standard FIP/WorldFIP Fieldbus architecture.
- Dual-Channel Physical Layers: Features two discrete 9-pin FIP Bus connection ports (Channel 1 and Channel 2), providing robust physical line routing options for distributed device drops.
- Optimized Power Footprint: Draws a steady 1.3 Amps from the local backplane at a tight 5.0 VDC ($\pm$0.1 VDC) supply tolerance, keeping maximum power consumption below 6.5 Watts.
- High Device Concentration: Addresses and scans up to 128 individual field devices, including Series 90-30 PLCs, remote I/O scanner racks, and computer terminals over a network loop spanning up to 1000 meters.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Number | IC697BEM741 |
| Communication Protocol | FIP / WorldFIP Fieldbus standard (EN50170 compliance) |
| Bus Baud Rate | 1.0 Megabits per second (Mbps) continuous transmission |
| Device Addressing Limit | Up to 128 remote fieldbus nodes or distributed I/O targets |
| Network Scan Interval | Deterministic full sweep in 5 ms to 50 ms (node-count dependent) |
| Physical Connections | 2x 9-pin FIP ports (Ch1/Ch2) | 1x 15-pin RS-232 serial interface |
| Chassis Rack Compatibility | Installs in single slots of IC697CHS782 and IC697CHS783 VME racks |
| Operational Climate | 0°C to 60°C (32°F to 140°F); 5% to 95% non-condensing relative humidity |
| Hardware MTBF Rating | Validated in excess of 250,000 continuous operation hours |
Installation & Maintenance Guide
Chassis Mounting & Slot Seating
Turn off all input power to the automation rack before beginning. Slide the IC697BEM741 card directly into an open physical slot of an IC697CHS782 or IC697CHS783 VME style chassis. Seat the rear card-edge contacts fully into the backplane connectors and firmly hand-tighten the integrated faceplate screws to provide solid grounding.
FIP Bus Line & Segment Routing
Connect network trunk segments to the twin 9-pin FIP bus ports. Ensure high-quality shielded twisted-pair cabling is utilized to maintain the 1.0 Mbps transmission speed over longer spans. Keep total unrepeated copper cable lengths below 1000 meters, accounting for signal attenuation factors and proper end-of-line termination resistors.
Hardware Reset & Maintenance
The faceplate features a rugged manual mechanical pushbutton that triggers an immediate local hardware reset. This allows system engineers to clear minor communication lockups or re-initialize the onboard network chips instantly at the panel door without requiring software overrides or resetting the master PLC controller.
Engineering Advantages
- Deterministic I/O Scanning: Refreshes and synchronizes data maps from all 128 remote stations systematically during every continuous bus cycle, preventing critical real-time variable skew.
- Local Configuration Retention: Features non-volatile configuration memory storage that securely holds complex network mapping variables and address settings through total facility power outages.
- At-a-Glance Diagnostics: Integrates a 6-LED physical display, featuring MODULE OK and RUN indicators at the top, supplemented by 4 channel-specific LEDs for real-time serial traffic and error tracing.
- Dedicated Firmware Uplink: Includes an independent 15-pin RS-232 serial interface port exclusively allocated for field-level firmware upgrades, insulating operational code from network data paths.
Technical FAQs
Q1: What software is required to configure the network maps on this module?
A1: The communication parameters and remote device maps are fully configured and managed using standard Logicmaster 90-70 (Windows variant) or CIMPLICITY Control 90 engineering software packages.
Q2: Can this controller operate on standard RS-485 serial networks?
A2: No. The IC697BEM741 is purpose-built to execute the specific FIP/WorldFIP fieldbus protocols (EN50170). It cannot interface directly with traditional Modbus RTU or generic RS-485 industrial lines without an inline protocol converter.
Q3: What causes the network scan interval to shift between 5 ms and 50 ms?
A3: The overall cycle time depends directly on the total number of live fieldbus nodes active on the network and the volume of cyclic data points requested. Fewer drops will drive the system toward the fast 5 ms benchmark, while a maxed-out 128-device bus triggers longer scan times.
Additional Specifications
- Green
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
-
Why Do Heavy Industries Trust GE Fanuc PLC and DCS Systems?
This article examines how GE Fanuc core components solve reliability gaps in heavy-load factory automation. It covers...
-
How Does Bently Nevada Predict Failures 180 Days in Advance?
Standard PLC and DCS systems often miss early vibration anomalies in rotating machinery, leading to 68% of sudden mec...
-
How Does ABB Omni-Measurement Eliminate Process Safety Blind Spots?
ABB Omni-Measurement closes process safety blind spots using predictive analytics and cross-validated sensing. Real r...