Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC695ALG306
IC695ALG306 GE Fanuc RX3i Isolated Thermocouple Input Module
Manufacturer: General Electric
Product No.: IC695ALG306
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC695ALG306 RX3i Isolated Thermocouple Input Module
GE Fanuc IC695ALG306 is a 6-channel isolated thermocouple input module for RX3i PACSystem. It supports thermocouple types B, C, E, J, K, N, R, S, and T with ±150mV or ±50mV input range.
Key Specifications
- Manufacturer: GE Fanuc
- Model: IC695ALG306
- Series: RX3i PacSystem
- Type: Isolated Thermocouple Input Module
- Channels: 6 individually isolated inputs
- Input voltage: ±150mV or ±50mV
- Resolution: 11.5 to 16 bits
- Update rate: 15ms to 120ms
- Weight: 0.35 kg
- Firmware required: RX3i CPU version 5.5 or later
- Mounting: RX3i universal backplane
Power Requirements
- 3.3V internal: 400 mA
- 5V internal: 150 mA
Supported Thermocouple Types & Temperature Ranges
- Type B: 300°C to 1820°C
- Type C: 0°C to 2315°C
- Type E: -270°C to 1000°C
- Type J: -210°C to 1200°C
- Type K: -270°C to 1372°C
- Type N: -210°C to 1300°C
- Type R: 0°C to 1768°C
- Type S: 0°C to 1768°C
- Type T: -270°C to 400°C
CJC Specifications
- CJC update frequency: 20 Hz fixed
- CJC temperature: Reported as separate channels
- Input attenuation: 3dB at 4.7 Hz
- First notch fixed setting: 10 Hz
Compatible Terminal Blocks (Sold Separately)
- IC694TBB032: Box-style terminal block
- IC694TBS032: Spring-style terminal block
- IC694TBB132: Extended box-style terminal block
- IC694TBS132: Extended spring-style terminal block
Environmental
- Operating temperature: 0°C to 60°C
- Storage temperature: -40°C to 85°C
- Humidity: 5-95% non-condensing
FAQs
-
How many channels?
6 individually isolated thermocouple input channels. -
What thermocouple types are supported?
B, C, E, J, K, N, R, S, and T types. -
What firmware is required?
RX3i CPU with firmware version 5.5 or later.
Additional Specifications
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Bench Tests Prove a Series 90-30 Module Works?
GE Series90 PLCs remain in service long after factory support ended in 2023, and unverified third-party spares carry ...
-
Is Staged Hot Cutover the Right Path for Legacy DCS Upgrade?
This article explains how continuous process plants migrate Yokogawa CS3000 to CENTUM VP through staged hot cutover, ...
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...